Page 9
Micro Grid Commands
ESC Z Reset Tablet.
Reconfigure Base of Switches.
Format #31, Table=0, Delta=0 and INC Value=0
ESC Q Set ASCII Format #15
Mode
ESC M 0
ESC M 1
ESC M 2
ESC M 3
ESC M 4
RUN (INC RUN)
POINT
(INC TRACK)
RUN PROMPT
DELTA MODE
Rate
ESC R 0
ESC R 1
ESC R 2
ESC R 3
ESC R 4
ESC R 5
ESC R 6
ESC R 7
ESC R 8
ESC D h
ESC I nnn
ESC F 0
ESC F 1
ESC F 2
ESC F 3
ESC C 0
ESC C 1
ESC C 2
1 PPS
2 PPS
5 PPS
10 PPS
20 PPS (NOTE: ON TEK WAS 30 AUTO WAS 20 PICKED SLOWER)
60 PPS
90 PPS
45 PPS (NOTE: AUTO WAS 100 AND TEK 45 PICK SLOWER)
130 PPS
SET ASCII DELINEATER TO character h. (NOTE: THIS COMMAND MAY NOT BE
IMPLANTED BASED ON RAM USAGE
SET INC VALUE=nnn. nnn=000 to 999
SET ORIGIN TO LOWER LEFT
SET ORIGIN TO NEXT POINT
SET ORIGIN TO CENTER
SET ORIGIN TO UPPER LEFT
SET RESOLUTION TO 200 LPI
SET RESOLUTION TO 254 LPI, 10 LPmm
SET RESOLUTION TO 1000 LPI