beautypg.com

Maintenance, Type designation, Inspection periods – GIN Boomerang 10 User Manual

Page 31: Validity of inspection

background image

31 /62

Boomerang 10

to rinse the glider, e.g. following a landing in the sea, gently wash it down inside and out with

fresh water. Frequent rinsing accelerates the aging process.

Maintenance

Type designation

GIN gliders have an exact identification on the underside of the wingtip or on the centre rib,

which is obligatory for all paragliders. The information required is set out in the airworthiness

requirements.
It is helpful to provide the type designation of the paraglider if you are contacting your Gin

Gliders dealer with any queries or ordering replacement parts or accessories, to ensure

accurate identification.

Inspection periods

Failure to observe the inspection periods shall render invalid the certification and warranty. A

properly completed logbook with details of all flying and training will help you to comply with

these periods.
The Boomerang 10 has to be inspected for a trim check by an authorized GIN agent during the

first 12 months.
The Boomerang 10 should be regularly inspected by a qualified professional every 100 hours
(including ground handling), or every 12 months, whichever comes sooner. Ground handling time

must be at least doubled when calculating the total hours of use because of the increased wear

and tear on the glider.
Subsequent inspections should be made annually. Inspection must be made not only of the

fabric, but also of the lines and all other parts of the glider. The maintenance instructions,

available on our homepage www.gingliders.com, have to be observed.
A full inspection will give you peace of mind and extend your glider's lifetime. Additional

inspections should be performed by a qualified person following a crash or violent landing on

the leading edge, or if you note a deterioration of performance or behaviour.
You should also check for any damage to your lines, sail, risers and connectors before each

flight.
We recommend replacing the line set at least every 150 hours.

Validity of inspection

It is very important that your glider is serviced at the required intervals throughout its entire

life. In order to benefit from Gin Gliders warranty:

 you must have your paraglider inspected by Gin Gliders or an inspection agent

authorised by Gin Gliders

 the documentation and the result of the inspection must be clearly identifiable (date

and place / name of the inspector) and be entered near the glider