INSTALLATION

POWER SUPPLY SETTING

FITTING A MAINS PLUG (U.K. only)

• Check that the type plate on the rear of your player

indicates the correct supply voltage.

• If your mains supply voltage is different, consult

your dealer or our Service Organisation.

Certain versions of this player are equipped with a

voltage selector (2), which enables you to set the

player to the correct mains voltage yourself. When
changing the voltage setting, it is also necessary to
change the mains fuse to one of the correct rating:

300 mA (slow blow fuse) for 110/127 V; 125 mA (slow
blow fuse) for 220/240 V.

CONNECTIONS

(Fig. 1)

1 Mains fuse holder

(not all versions)

See ’Power supply setting’.

2 Voltage selector

(not all versions)

See ’Power supply setting’.

3 RC5IN/OUT

Use this connection for;

-

connecting up the equipment when you are

incorporating the player in a HiR system with its
own remote controi system.

- connecting the remote control receiver EM 2200,

available as an accessory.

(Not available in the U.K.)

4 DIG(ital) OUT

For digital signal processing or future applications

such as CD-i. This output supplies a digital signal
and can therefore only be connected to an input

which is suitable for this signai. Use here a iead
with one cinch-plug on either end.

Never

connect this socket to a non-digitai input of

an amplifier, such as AUX, CD, TAPE, PHONO, etc!

5 OUTL/R

For the connection cable to the amplifier.

• Insert a red plug into the ’R’ socket and the other

plug into the ’L’ socket.

• Insert the two other plugs into the corresponding

sockets of the CD or AUX input of your amplifier.

You can also use the TUNER or TAPE IN connec­

tion, but

never

the PHONO input!

6 Connection for the mains lead

The wires in the mains lead are coloured:

Blue - Neutral Brown - Live

As these colours may not correspond with the colour

markings identifying the terminals in your plug,
proceed as follows:

• The Brown wire must be connected to the terminai

which is marked with the letter L or coloured Red.

• The Blue wire must be connected to the terminal

which is marked with the ietter N or coloured Black.

No connection

should be made to the earth terminal

of the plug!

For 13 A plugs, conforming to BS 1363, use a 3 A

fuse. For other plugs, use a 5 A or lower fuse in the

plug, adapter or at the distribution board.