Setting example) – Futaba GY501 User Manual
Page 18

19
B
EFORE
U
SE
85%
15%
70%
30%
70%
40%
NORM
IDL1
IDL2
(Setting Example)
Adjust the gyro gain at each the Idle-Up swtch position at the Gyro Mixing
setup screen. The following shows a setting example in the CMT mode.
Select the “ON”
mode.
Select the Idle-Up
switch.
Switch position
Sensitivity rate
Set the “NORM”, “IDL1” and “IDL2” gains at each setup screen.
Use the following values as the sensitivity setting standard:
AVCS mode
When set over 50%, the GY501 operates in the AVCS mode and when
set under 50%, the GY501 operates in the Normal mode.
Actual gain
Hovering
Flight
Normal mode