Brake/reverse operating instructions, Cancelling the reverse function, Checker led display – Futaba 3PL 2.4GHz FHSS User Manual
Page 21: Protection circuit operation
21
3PL-2.4G Functions
MC230CR/MC330CR
BRAKE/REVERSE OPERATING INSTRUCTIONS
Operation can be switched to reverse operation by returning the throttle trigger (or throttle stick) from the brake
position to the neutral position.
CANCELLING THE REVERSE FUNCTION
The amp reverse function can be cancelled by the following method so that the model can be used even in races
that prohibit reverse running. (Brake operation only)
While pressing
the pushbutton switch,
set the power switch to ON.
ON
MC230CR / MC330CR
(Pushbutton switch operation)
(Power switch)
1
Reverse
function
cancellation
* When desired, you can enable the cancelled reverse
function by repeating the operation shown at the left.
(The reverse function is switched alternately.)
CHECKER LED DISPLAY
The amp operates linearly in proportion to the amount of forward, reverse, and brake operation. The amp operating
state can be checked with the checker LED as shown below.
PROTECTION CIRCUIT OPERATION
The following protection circuits are built into the MC230CR / MC330CR. When a protection circuit operates,
remove the cause before operating the model again.
Operation
Amp power ON
Checker LED display
(Reverse operation set)
Single blink
(Single confirmation beep)
(Only brake operation set)
Off
On
On
Off
Off
Double blink
(Two confirmation beeps)
Blinks. (Confirmation
beep also sounds.)
* Confirmation beep only sounds when the motor was connected.
High point
Neutral point
Brake MAX point
*Becomes brighter nearer the high
point.
*Becomes brighter nearer the
brake MAX point.
*Not used with PCM receivers.
*When the transmitter is OFF, this function is
not performed in environments such that the
servo operates erroneously.
When an overcurrent flows due to an output short circuit, etc., the overcurrent protection circuit automatically
limits the current to protect the FET.
Remove the cause of the short circuit, etc. before operating the model again.
(Amp power left on alarm)
When the transmitter power
was turned off first.
Forward
Reverse
/brake
Overcurrent
protection
When abnormal heating of the FET due to an overload, etc. is detected, the heat protector operates so that
the speed is gradually reduced.
When the FET temperature drops, the heat protector automatically resets. However, remove the cause
of the overheating before operating the model again.
Heat protector
When the Nicd battery voltage drops, this function limits the motor output current and ensures steering operation.
After the speed drops, immediately recover the vehicle.
Low voltage
operation