Energenics Kartwash Premier User Manual
Page 5

CONTROL KEYPAD
The Control Keypad is a multi key, multi function panel that allows system
change and system error messaging from the PLC. The Control System is UL
listed and approved. All output and monitoring is controlled by the programmable
Logic Controller. The LCD message center informs the operator of the cycle
point and alerts to system errors. All of the system sensors, photo eyes and
doors send error messages when problems occur.
CONTROL PANEL OPERATION
Function Keys, F1-F6
• F1:
This is the START button, pushing F1 starts the cycle. The words
Wash will appear, the seconds of the wash cycle will count down. It then
displays Rinse, Rest (drain) and Dry all with the remaining countdown in
seconds.
• F2: Not
assigned.
• F3:
This is the programming function key. Push F3, enter the password
code (9552), press page down to find the program you desire to change,
press clear, enter new data with numeric keys, and press enter. It is not
uncommon to desire a longer blowdown for dryer carts. Press F3, enter
9552, press page down to display the blowdown duration, press clear,
enter the new time in seconds, and press enter. The new timing is set.
• F4:
This is the manual stop button. Pressing F1 after an F4 stop will
restart the cycle from the beginning. NOTE: The Emergency Stop
Buttons are push to activate and pull to reset.. As in the F4 stop, pushing
F1 restarts the program from the beginning.
• F5: Not
assigned.
• F6:
Program exit. After changing the program with the F3 key, F6 must
be pushed to exit the programming mode and return to the run mode.
Pushing F1 after F6 will restart a wash cycle.
5