UTILITY CONNECTIONS: (Refer to Drawing KW100)
The electrical conduit, water pipe and air line should be connected through the
ceiling to the component, utility section of the Kartwasher. Drill holes directly
above the internal connection locations. Caulk around the ceiling holes inside
and out after connecting.
1) Connect the power to the internal safety box complying with local electrical
codes. (See Kartwash component chamber drawing KW100)
2) Connect the hot water to the ¾”NPT water connection on the poly tank. (See
Kartwash component chamber drawing KW100)
3) Connect the compressed air to the ¼” air connection. (See Kartwash
component chamber drawing KW100)
4) The exhaust outlet (20”X20”) in the roof of the wash chamber should be
ducted to the outside of the laundry.
5) The inlet (20”X20”) on the utility cabinet roof may be connected to fresh air or
to the clean side of the laundry.
For Kartwashers with built-in sumps in the bottom of the wash chamber
connect the 2” drain (placement specified when ordered) to the main drain of
the laundry per applicable codes.
3