WARNING AND CAUTION

IF INSTALLING OPTIONAL VACUUM PAY

ATTENTION TO PAGE 15

You have purchased the finest lint filter available for your facility. Please follow
these instructions to ensure a safe long life for your filter and facility.

FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN AN UNSAFE

OPERATING CONDITION, INCLUDING THE POSSIBILITY OF FIRE.


DO NOT OPERATE ANY DRYER CONNNECTED TO THIS FILTER
WITHOUT BEING CERTAIN THE FILTER STARTUP HAS BEEN
COMPLETED AND THE FILTER IS IN OPERATING CONDITION.

Insure it is installed in compliance with local codes.
Step 1. Install the compressed air (Fire suppression plumbing if ordered), and

piping system(s) including solenoid valves. If the filter is in position,
make all final connections.


Step 2. Install sheet metal and ducting.

START UP AND OPERATION INSTRUCTIONS

Inspect the filter installation. Is it complete? Review the entire installation
requirements prior to startup.

1. Test the blow down cycle (turn the dryer on and off).

Watch the pressure gauge. It should start at 100psi and should not drop below
60psi during the 6-10 second cycle.

The rotor should turn 6-12 times during blow down. The rotor propulsion is
adjustable by increasing the number of horizontal holes on the top horizontal
portion of the rotor end.

3. Review maintenance requirements and establish a regular PM schedule.