Maintenance Schedule

Every 100 Hours of Operation

Daily

X
X

X

All maintenance to

be performed by

qualifi ed

personnel.

Visual Inspection of

Entire Tool

Check chisel for

damage/uneven wear

X

X

X

X

Lubricate

Clean Dust & Dirt

Off of Tool

Check “O” Rings

Replace “O” Rings

Flush Tool

Before Operation

As Required

Every

Tool Flush

Operational Keys to good equipment care and long life...

1. Before each use, check and insure all hardware, nuts, bolts and fi ttings are tight

and not worn or damaged. If damaged or missing hardware is noted, it should be

replaced before the tool is put back into service.

2. Check the maintenance instructions for important information about lubrication

intervals. Remember, equipment used in a dusty environment has more frequent

lubrication requirements than equipment that is not used in a dusty environment.

3. After each days use, the chisel scaler should be cleaned. When cleaning, cover

any openings to prevent contaminants from entering the equipment.

This manual is related to the following products: