3. INSTALLATION and CONNECTION
Installing a MPAGE4 unit consists of the following steps:
1.
Installation of wiring using a standard CAT5 cable between the BASE connector of
the MPAGE4 (7) and the PAGER connector on the rear panel of the MIMO54.
Wiring of RJ-45 connector
Pin 1 to Pin 1
White/orange
MIC+
Pin 2 to Pin 2
Orange
MIC-
Pin 3 to Pin 3
White/green
GND
Pin 4 to Pin 4
Blue
VCC (+10V)
Pin 5 to Pin 5
White/blue
ZONE 1
Pin 6 to Pin 6
Green
ZONE 2
Pin 7 to Pin 7
White/brown
ZONE 3
Pin 8 to Pin 8
Brown
ZONE 4
The cable transmits the zone selection control signals as well as the audio signal of
the goose-neck microphone and the signal for the carillon melody, if activated. The
phantom power required by the MPAGE4 unit is also supplied by the MIMO54 using
the same cable.