Ecler MPAGE16 User Manual
Page 10
10
of whether it was send or not to other zones). This flashing stops when any one of the
following keys is pressed:
o
Relevant zone key, remaining selected (green)
o
ALL key, keeping this zone and the other ones selected (green)
o
CLEAR key, releasing all zones
In a two console configuration with equal priority, the first one that captures one or several
zones has priority for the duration of paging, keeping these zones busy until their release. While this
console is paging, if the other console tries to communicate with any zone hold by the first one
(overlapping zones held by the first console), these zones LEDs will flash in orange to indicate
paging didn’t success. At the end of the priority paging, these zones LEDs still flash in orange,
alerting the user that the message has not been totally paged to this particular zone (regardless of
whether it was send or not to other zones). This flashing stops when any one of the following keys is
pressed:
o
Relevant zone key, remaining selected (green)
o
ALL key, keeping this zone and the other ones selected (green)
o
CLEAR key, releasing all zones
As long as PAGE key is held pressed, zone selection can’t be edited, and therefore MIMO-
88 unit will ignore all messages relating to zone selection. During this time interval, functions of ALL,
CLEAR, F1 and F2 keys will also be ignored.
4.5. F1 et F2 special function programmable keys
"F1" and "F2" are two programmable keys, useful for launching MIMO88 functions
programmed from EVENTS section of EclerNet Manager software, such as for example user
memory ("preset") recall or GPO output (relay) status change
When the MIMO-88 unit is informed that any of these keys has been pressed, it launches
the programmed function and reply to MPAGE16 unit, confirming the function status, in order to turn
the green LED on or off according to the ON or OFF status. If the special function is not available,
the green LED momentary flashes.
The same special function can be assigned to F1 or F2 keys of different consoles. If the
special function of a particular console is activated / deactivated via a console (or directly from
EclerNet Manager application), F1 and F2 LED status will be automatically updated on all consoles
involved.
As long as PAGE key is held pressed, F1 and F2 functions are deactivated.