beautypg.com

Ecler ALMA26 User Manual

Page 8

background image

8

The special combinations of the setup keys are:

 Left and right MENU simultaneously for 2 seconds: access to the unit's SETUP menu (see

chapter 9)

 Left and right PARAM simultaneously for 2 seconds: access to the unit's front panel

locking/unlocking and password management (see chapter 10)

 SHIFT + left MENU (EXIT): bring back to the main screen, from any menu
 SHIFT + right MENU (CANCEL): undo the last parameter editing and recall the value as

before the change

 SHIFT + left PARAM (RECALL): load one of the presets (device setups) stored in the memory

 SHIFT + right PARAM (SAVE/ENTER):

o SAVE: save a preset (device setup) into memory
o ENTER: confirm a critical modification (e.g.: password change)

 Right MENU, kept pressed while powering up the unit: load preset #1, designed to be edited

and saved in order to be used as booting setup. This operation is allowed even when the
unit's front panel is locked with a password

 Holding down the SHIFT key while powering up the unit: displays the "Power OFF to recover

factory defaults" message. After turning off and on again, default parameters ( factory
defaults)
are restored, erasing all user data, settings and presets from the unit's memory

USB Connector

A type-B USB connector (11) is used to connect the ALMA26 to a PC and perform the

unit management and control from EclerCOMM Manager software.