beautypg.com

Ecler MPA 6-80R User Manual

Page 13

background image

13

4.4. Connection of the VCA control

As already mentioned in the introduction of this manual, the signal attenuation level for each of the

input channels can be set using the following methods:

a) Using a remote potentiometer with nominal resistance between 10k

 and 50k.

b) Using a device that generates a control voltage from 0 to 10V DC.
c) Using remote relays/dry contacts.

NOTE: it is possible to connect a maximum of 16 inputs to one control potentiometer. It is

necessary that the ground terminals of all amplifiers are connected.

The connection cables can be up to 500m long if a section of 0,5mm

2

is used.

Consult the available accessories at your ECLER dealer or at www.ecler.com.
Remember that the VCA circuit is disabled by default. If you need to use it, you have to activate it

using the internal jumpers (see configuration diagram).

4.5. Indicators

The SP signal presence indicators (7, 8, 9, 10, 11, 12) light up when the input signal reaches

approximately -40dBV.

The CLIP indicators (13, 14, 15, 16, 17, 18) light up when the output signal for the speakers is

-1,5dB below the actual clipping threshold. This clipping system watches for eventual supply voltage
variations, thus giving always an accurate clipping indication, regardless of mains voltage deviations. It is
normal that when operating at high output power, the CLIP indicators light up in synchronisation with the
low frequencies, which carry the most energy. Nevertheless, you should avoid that the CLIP indicators
are lit continuously.


5. CLEANING

The front panel should not be cleaned with dissolvent or abrasive substances because

silk-printing could be damaged. To clean it, use a soft cloth slightly wet with water and neutral liquid
soap; dry it with a clean cloth. Be careful that water never gets into the amplifier through the holes of the
front panel.

This manual is related to the following products: