Ecler CA120 User Manual
Page 50
50
8. TECHNICAL CHARACTERISTICS
8. CARACTERÍSTICAS TÉCNICAS
8. CARACTÉRISTIQUES TECHNIQUES
8. TECHNISCHE DATEN
POWER (STEREO/MONO)
2x56W@4
1% THD
2x68W@4
10% THD
2x34W@8
1% THD
2x41W@8
10% THD
Frequency response
15Hz - 30kHz (-3dB)
THD+Noise @ 1kHz Full Power SPEAKER OUT
<0.15%
THD+Noise AUX OUT
<0.02%
Channel crosstalk @ 1kHz
>65dB
Inputs Sensitivity nom/Impedance
LINE1
0dBV (-6dBV*)/>8k
LINE2
LINE3
0dBV (-6dBV*)/>8k
0dBV (-6dBV*)/>8k
MICRO
(BAL)
-20 to -50dBV/>1k
CMRR
MICRO (BAL) >65dB @ 1kHz
Outputs Level/Minimum Load
AUX OUT
-2dBV/10k
Tone control (LINE & MIC)
BASS
100Hz ±10dB
TREBLE
6KHz
±10dB
Signal Noise Ratio
LINE
>85dB
MIC
(BAL)
>65dB
Talkover TIME
2
Sec**
DEPTH
-30dB**
Microphone Noise Gate
20-30 below max.**
Phantom voltage
+24VDC/10mA max.*
RS-232
BAUD RATE
9600 (fixed)
DATA
8
bits
PARITY
NONE
STOP
BITS
1
FLOW
CTRL
NONE
ANALOG REMOTE (0-10V. based)
Volume & Input/preset**
selection
INFRARED REMOTE
Volume & Mute
Mains (Using supplied DC adapter)
90-264VAC 47-63Hz
Power consumption (pink noise, 1/8 power @ 4ohm)
33VA/24W
Power consumption (pink noise, 1/3 power @ 4ohm)
58VA/52W
Power consumption Stand By (time 2 minutes)
<2.5W
Dimensions WxDxH
160x210x48mm
Weight
950g
*Internally selectable **Software selectable