beautypg.com

Action2, Amplifier, Action – D.A.S. Audio Action Series User Manual

Page 19: Action m12a , action, Amplificador de

background image

AMPLIFIER

Description
1
) INPUT :

1/4” Jack+XLR c

:

1 or S =GND (ground).
2 or T =(+) Non inverted input.
3 or R =(-) Inverted input.

2) LOOP THRU (except SUBs):

XLR-type output signal connector for connecting several

units together and sending them all the same signal.
2) SATELLITE OUTPUT (only SUBs):

A and B, XLR-type output signal connectors for

connecting several units together and sending them all the
same input signal or filtered signal (by using THRU/HPF).
3) LIMIT :

Red LED indicates amplifier saturation. Amplifier limiter

indicator lights.
4) SIGNAL :

Green LED indicates signal presence.

5) ON :

Green LED (blue for

action 18A) indicates that the unit is

ON.
6) LEVEL / SUB LEVEL :

Potentiometer for adjusting the unit level.

7) MAIN / MONITOR (only

action M12A) / BOOST / FLAT :

Button for switching between two types of frequency

response. Press the button to use the unit without
subwoofer. Please note that the unit will therefore reach its
limits sooner.
8) MIC / LINE :

Button for switching between microphone and line

sensitivities. NEVER PRESS THIS BUTTON WITHOUT
FIRST REDUCING THE LEVEL OF THE UNIT TO AVOID
EXTREMELY HIGH SPL.

ombined socket-type input signal

connector. This is a balanced connector just like the LOOP
THRU connector with the following pin assignments

9) LOGO OFF / ON :
Press the button to illuminate the logo.
10) AC INPUT :

Standard IEC-60320 (only

action 18A) or PowerCon NAC3FCA mains

connector (inserted, rotated and locked for ON). Only use this equipment
with an appropriate mains cord.
11
) POWER :

Mains power ON/OFF switch.

12) THRU/HPF :

‘SATELLITE OUTPUT’ selector to switch between full range signal or pass

filter with cut-off frequency of 100 Hz.
13) LINE SELECT (only

action 18A) :

Mains voltage selector (115V AC or 230V AC). Before operating, verify

the voltage selection.
14) LOW-PASS CROSSOVER :

Button for adjusting the upper cut-off frequency for the subwoofer unit. We

recommend a cut-off frequency of 100 Hz.
15) PHASE :

Switch for inverting the phase of the unit.

16) FUSE (only

action 18A) :

Fuse holder. Only use the recommended fuse type and size.

17) PRESET DEEP/LOUD (only

action 218A) :

Button for switching between two types of frequency response, DEEP or

LOUD.
18) AC OUTPUT (only

action 218A) :

PowerCon NAC3FCB connector for AC loop thru allows up to 6 units when

using a 230V version (see unit’s label)). Only use this equipment with an
appropriate mains cord.
19
) Fan (only

action 218A).

action M12A, action

12A, action 15A

&

action 215A

amplifiers

action

18A

amplifier

action2

18A

amplifier

19

Manual del Usuario

/ action active / User’s Manual

WARNING: TO REDUCE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE
WARNING: THIS PRODUCT MUST BE GROUNDED
REFER TO INSTRUCTIONS MANUAL FOR CONNECTION
NO USER SERVICEABLE PARTS INSIDE

ATENCIÓN: PARA REDUCIR EL RIESGO DE FUEGO O DESCARGAS ELÉCTRICAS NO
EXPONGA ESTE EQUIPO A LA LLUVIA NI A LA HUMEDAD
ATENCIÓN: ESTE APARATO DEBE CONECTARSE A TIERRA
VEASE MANUAL DE INSTRUCCIONES PARA LA CONEXIÓN
NO EXISTEN PARTES AJUSTABLES POR EL USUARIO EN EL INTERIOR DEL EQUIPO

CAUTION

ATTENTION

risk of electric shock

do not open

danger d’electrocution

ne pas ouvrir

CAUTION

ATTENTION

HOT SURFACE,

AVOID CONTACT

TEMPERATURE ELEVEE!

NE PAS TOUCHER!

N1918

D.A.S. AUDIO S.A. (Valencia) SPAIN

INPUT

SIGNAL

SATELLITE

OUTPUT

INPUT A

INPUT B

OUTPUT A

OUTPUT B

T

H

R

U

H

P

F

L

IM

IT

S

IG

N

A

L

O

N

P

H

A

S

E

180º

POWER

115/230V 50/60HZ 800W
T5AL 250V FOR 230V INPUT
T9AL 250V FOR 115V INPUT

SUB LEVEL

MIN

60Hz

MAX

160Hz

LOW-PASS

CROSSOVER

100Hz

2

1

6

14 15

12

5

4

3

13

10

16

11

115V

3.6A 50Hz/60Hz

AC INPUT

MAX. 3 UNITS IN PARALLEL

AC OUTPUT

OUTPUT A

OUTPUT B

HPF/THRU

OFF/ON

SATELLITE X-OVER

LOGO

LIMIT

SIGNAL

ON

DEEP/LOUD

PRESET

- +

POLARITY

CAUTION

DO NOT EXPOSE THIS EQUIPMENT

TO RAIN OR MOISTURE

RISK OF ELECTRIC SHOCK

DO NOT OPEN

N1918

T25 A L 250V FUSE

FOR CONTINUED PROTECTION

AGAINST RISK OF FIRE REPLACE

ONLY WITH THE SAME TYPE

LEVEL

+6

-oo

0

LOW-PASS

160Hz

100Hz

125Hz

action

218A

D.A.S. Audio, s.a. (Valencia)

MADE IN SPAIN

22000001

19

6

3

4

5

17

15

14

2

1

12

18

16

10

9

230V

1.2A 50Hz/60Hz

CAUTION

DO NOT EXPOSE THIS EQUIPMENT

TO RAIN OR MOISTURE

RISK OF ELECTRIC SHOCK

DO NOT OPEN

LIMIT

SIGNAL

ON

LEVEL

MIC/LINE

+12

-oo

0

OFF/ON

LOGO

LOOP THRU

INPUT

N1918

action

12A

BOOST

/ FLAT

22000001

D

.A

.S

.

A

u

d

io

,

s

.a

.

(V

a

le

n

c

ia

)

M

A

D

E

I

N

S

P

A

IN

1

2

3

4

7

6

8

5

10

11

9

Amplificador de

action

8A

LIMIT

SIGNAL

ON

LEVEL

+12

-oo

0

0

LOOP THRU

INPUT

BOOST

/ FLAT

MIC/LINE

OFF/ON

LED

action

8A

1

2

3

4

5

6

7

8

9