5

INSTALLATION & SET-UP

THE INSTALLATION OF THIS APPLIANCE MUST BE IN ACCORDANCE WITH:

1) All applicable local codes, or in the absence of local codes;
2) i) Canada: must conform to current National Standard CSA B149.1&.2 - natural

gas/propane installation code.

ii) U.S.A.: must conform to national Fuel Gas Code, ANSI Z223.1, 1999 or latest

edition.

WARNING!

DO NOT operate this appliance under overhead, unprotected construction. This
appliance shall be used only in a well ventilated space and shall not be used in a building,
garage, or any other enclosed area.

Minimum clearance to adjacent combustible materials:
• 12 inches from side(s)
• 24 inches from back (See Fig. 1 pg. 6.)
• This appliance is not suitable for use on combustible floors without the table unit.
• Always level your MCB front to back & side to side.
• Always keep the area surrounding your charbroiler clear of all combustible materials,

gasoline, or other flammable liquids.

• Use your charbroiler OUTDOORS in a well-ventilated space, preferably 10 ft. from

dwellings or outbuildings.

• Casters must be locked when appliance is in operation.
• Always keep 1” of water in grease trays.
• Do not transport grill units in set-up position.
• Do not overload tables. (325lb. max. static load).