Operating Conditions
This table illustrates environmental conditions:
Hardware Specifications
The following table illustrates hardware specifications:
Electromagnetic Compliance
This table lists electromagnetic compliance
certifications:
Technical Support
If you need technical support, contact Comtrol using one
of the following methods.
Corporate Headquarters:
•
email:
•
FAX: (651) 631-8117
•
Phone: (651) 631-7654
•
FTP
•
Web Site:
http://www.comtrol.com
Comtrol Europe:
•
email:
•
FAX
: +44 (0) 1 869-323-211
•
Phone: +44 (0) 1 869-323-220
•
Web
Comtrol has a staff of technical support specialists
available to help you.
First Edition, December 21, 1998
Copyright © 1998. Comtrol Corporation.
All Rights Reserved.
Comtrol Corporation makes no representations or
warranties with regard to the contents of this reference
product or to the suitability of the Comtrol product for
any particular purpose. Specifications subject to change
without notice. Some software or features may not be
available at the time of publication. Contact your
reseller for current product information.
Trademark Notices
Comtrol and RocketModem are trademarks of Comtrol
Corporation.
RocketPort is a registered trademark of Comtrol
Corporation.
Micro Channel is a registered trademark of
International Business Machines Corporation.
Other product names mentioned herein may be
trademarks and/or registered trademarks of their
respective owners.
2000003 Revision A
Environmental Conditions
Value
Air temperature:
System on
System off
0 to 40
o
C
-20 to 85
o
C
Altitude:
0 to 10,000 feet
Humidity (non-condensing):
System on
System off
8% to 80%
20% to 80%
Description
Specification
Baud rate
300 to 56 Kbps
Bus interface
PCI
Card dimensions (meets PCI
specifications)
12.4” by 4.2” (w x h)
Cards per system
4
Current consumption (+5V):
RocketModemII 4
RocketModemII 6
1.7A max
2.3A max
Device driver control:
Data bits
Parity
Stop bits
7 or 8
Odd, Even, None
1 or 2
Heat output:
RocketModemII 4
RocketModemII 6
29 BTU/hr
39.2 BTU/hr
Interrupt (driver dependent)
None, 3, 4, 5, 9, 10,
11, 12, and 15
Mean time between failures:
RocketModemII 4
RocketModemII 6
18.3 years
13.7 years
Modems per card
4 or 6
Modems per system
4 to 24
Power consumption:
RocketModemII 4
RocketModemII 6
8.5 W
11.5 W
Telco connector
RJ11
Weight (card only):
RocketModemII 4
RocketModemII 6
10 oz
11 oz
Electromagnetic Compliance
Status
Emission:
Canadian EMC requirements
FCC Class B Certification
Yes
Safety:
UL Listed
Yes
FCC Part 68 Certification
Yes