beautypg.com

Vermont castings, majestic products def/ defd26 – Vermont Casting DEFD26 User Manual

Page 7

background image

7

10005581

Vermont Castings, Majestic Products DEF/ DEFD26

1. Turn

OFF

power to the unit by unplugging the power

cord.

2. Let fireplace cool if it has been operating.

3. Remove the four (4) screws securing the bottom

louvre. Pull the louvre up and lift it out.

4. Examine the bulbs to determine which bulb needs to

be replaced.

5. While holding the socket, unscrew defective bulb(s).

6. Install the new light bulb(s) by screwing it in while

holding the socket.

7. Reinstall the bottom louvre. Follow the above

procedure in reverse order.

WARNING: Do not exceed 60 Watts per
bulb. Use of higher-rated bulbs may result
in a fire, causing property damage or
personal injury.

Maintenance of Motors

The motors used on the fan and the flame generator
assembly are prelubricated for extended bearing life
and require no further lubrication. However, periodic
cleaning/vacuuming of the fan/heater unit is
recommended.

WARNING: Make sure the power is
turned

OFF

before proceeding.

Fig. 2 Trim kit installation

DEF26_3D

Trim Kit Installation

1. Peel all plastic from the Trim Kit Assembly.
2. Press the Trim Kit Assembly onto the front of the

fireplace. To facilitate the installation process, these
pieces are magnetized. Align the top of the Trim Kit
Assembly with the top of the fireplace.

Replacing the Light Bulbs

This fireplace uses two (2) clear 120 Volt, 60 Watt,
E-12 socket base light bulbs (small base, chandelier
candle type). The 60 Watt bulbs are located under the
logset/ember bed. For convenience, if one (1) of the
bulbs burns out, it will be prudent to replace both of the
light bulbs.

This manual is related to the following products: