Alarm recording, Connection, Operation – Toshiba KV-5024A User Manual
Page 15: Function
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Alarm Recording
This unit is capable of "Alarm Recording". If the alarm input is connected to a door switch, this VCR will automatically switch
from the time lapse mode to continuous recording in the 2-hour mode.
Time Lapse Recording
1 2 or 24H Mode
Alarm Recording
2H Mode
Time Lapse Recording
12 or 24H Mode
Alarm Recording
2H Mode
Start of Record 3
• REC PAUSE mode
• STOP mode
• REC PAUSE mode
• STOP mode
^ Alarm Signal Input^
Alarm "signal Input ^
Connection
Operation
Function
The alarm switch
shown below.
is connected as
Set the alarm recording time
selector switch to the desired
recording time length (15 sec, 30
sec. and 3 min.} when receiving an
alarm signal.
ALARM REC TIME
15
s
8
c
. 3min.
» <
[m
Alarm signal input: short circuit *
Alarm reset input; short circuit *
* The short circuit should last at least
0,5 seconds.
When set to 15 sec., recording will
take place in 2-hour mode for 15 sec.,
and return to the previous time mode.
When set to 30 sec., recording will
take place in 2-hour mode for 30 sec.
When set to 3 min., recording will take
place in 2-hour mode for 3 min.
When alarm recording is completed,
the alarm display will blink.
If the ALARM RESET and GROUND
terminals are short-circuited, alarm
recording will be cancelled.
A voltage of 5 V is fed from the
ALARM OUT terminal during an alarm.
When an alarm signal is input with the
buzzer switch set to ON, the buzzer
sounds continuously.
Notes
If the alarm input terminals short-circuit for more than the
specified time, alarm recording continues during that time.
During alarm recording, on-screen display appears in two
lines.
14