Crown Boiler MWC116ENL User Manual

Page 86

background image

84

Key no.

Description

Spare part code

141

Flue thermostat

BI1262 104

142

Twin fl ue cover plate

BI1366 114

143

Gasket - Air intake twin kit

BI1016 101

144

Air restrictor d. 45 mm

BI1406 129

145

Return group (Model c.h. only)

BI1171 107

146

By-pass pipe (Model c.h. only)

BI1171 106

147

Flow group kit (Model c.h. only)

BI1171 103

148

Safety valve connection pipe (Model c.h. only)

BI1262 140

149

Main exchanger outlet pipe (Model c.h. only)

BI1262 141

150

Control panel box (Model c.h. only)

BI1555 115

151

Flow switch, temp. probe and modulator cable (Model c.h. only)

BI1615 118

152

Pump cable (Model c.h. only)

BI1615 119

Appendix A: Special Requirements For Side-Wall Vented Appliances

In The Commonwealth of Massachusetts

IMPORTANT

The Commonwealth of Massachusetts requires compliance with regulation 248 CMR 4.00 and 5.00 for
installation of side-wall vented gas appliances as follows:

(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or struc-

ture used in whole or in part for residential purposes, including those owned or operated by the Com-
monwealth and where the side wall exhaust vent termination is less than seven (7) feet above fi nished
grade in the area of the venting, including but not limited to decks and porches, the following require-
ments shall be satisfi ed:

1. INSTALLATION OF CARBON MONOXIDE DETECTORS.
At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber
or gasfi tter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up
is installed on the fl oor level where the gas equipment is to be installed. In addition, the installing plumber
or gasfi tter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is
installed on each additional level of the dwelling, building or structure served by the side wall horizontal
vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of
qualifi ed licensed professionals for the installation of hard wired carbon monoxide detectors.

a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space

or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed
on the next adjacent fl oor level.

b. In the event that the requirements of this subdivision can not be met at the time of completion of

installation, the owner shall have a period of thirty (30) days to comply with the above requirements;
provided, however, that during said thirty (30) day period, a battery operated carbon monoxide de-
tector with an alarm shall be installed.