6

Installation

Hot Water Connection

NOTE:

Plumbing connections must comply with all national and/or local plumbing and sanitary codes.

The hot water connection is located at the lower

left-rear side of the dishwasher. A 3/4" line

strainer and pressure regulating valve (PRV)

were installed at the factory.

1. The size of the incoming hot water line

should be 3/4" or larger.

2. The PRV should be adjusted to supply a

minimum flowing pressure of 20 PSI/138

kPA during the final rinse. The maximum

flowing pressure must not exceed 25

PSI/172 kPa during the final rinse.

3. The temperature of the incoming

hot water must maintain a minimum

temperature of 140°F/60°C for a

40°F/22°C rise booster or a minimum

temperature of 110°F/43°C for a

70°F/39°C rise booster.

4. A manually operated 3/4" or larger

shut-off valve should be installed in the

incoming line as close to the dishwasher

as possible for servicing.

Drain Connection

The incoming hot water line is a 3/4" NPT connection.

The drain water connection is a 2" slip-fit hose

connection and is located at the center-rear of

the machine base. It is a gravity drain.

1. The dishwasher drain is 2" O.D. hose

connection.

2. A optional drain water tempering kit

is available (consult the factory).

3. Drain water flow is controlled by an

automatic electrically operated drain

valve.

4. The floor sink and/or drain plumbing

must be able to accommodate a

maximum drain flow rate of

20 US gpm / 17 Imp gpm / 76 Lpm.

The drain is a 2" slip-fit hose connection.