Installation
Electrical Connections
ATTENTION
A qualified electrician must connect the main incoming power to the dishwasher in accordance with all
local codes and regulations or in the absence of local codes in accordance with the National Electrical
Code.
THREE PHASE
POWER CONNECTION
208-240V/60/3
LINE IN
L1
L2
L3
GRD
Standard Dishwashers are shipped from
the factory for 3-phase operation.
To connect the dishwasher for 3-phase
operation:
1. Remove the top-mounted control
cabinet cover and locate the main
terminal block in the left-rear
corner of the cabinet.
2. Refer to the
Machine Electrical
Connection Data Plate located
near the main terminal block and
make sure that the incoming
power supply matches the
machine's electrical requirements.
3. Connect the incoming 3-phase
power as shown in the illustration
to the right.
4. Re-install the control cabinet
cover.
WARNING:
Electrocution or serious injury may result when working on an
energized circuit.
Disconnect power at the main breaker or service disconnect
switch before working on the circuit.
Lock-out and tag the breaker to indicate that work is being
performed on the circuit.
Three Phase Operation
Main Terminal Block
Main Terminal Block Location
NOTE:
Refer to the next page for 3-phase to