beautypg.com

Facts to consider about the location, Acaution, Awarning – Kenmore POWER MISER 153.336951 User Manual

Page 9: Installation instructions (cont’d)

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Installation Instructions (cont’d)

Facts to Consider About the
Location

You should carefully choose an indoor location for the new
water heater, because the placement is a very important consid­
eration for the safety of the occupants in the building and for
the most economical use of the appliance. This water heater is
not for use in mohile homes or outdoor installation.

Whether replacing an old water heater or putting the water

heater in a new location, the following critical points must be
observed.

• The location selected should be indoors as close as practical to

the gas vent or chimney to which the water heater vent is
going to be connected, and as centralized with the water pip­
ing system as possible. The water heater, as all water heaters,
will eventually leak. Do not install without adequate drainage
provisions where water flow will cause damage.

ACAUTION

WATER HEATERS EVENTUALLY LEAK: Installation of the
voter heater must be accomplished in such a manner that if
the tank or any connections should leak, the flow of water will

not cause dam:^ to the structure. For this reason, it is not
adwsable to instil the water heater in an attic or upper floor.

When such locations cannot be avoided, a suitable drain pan

should be installed under the water heater. Drain pans are
available at your local Sears store. Such a drain pan must be
not greater than I

'A

inches deep, have a minimum length and

width of at least

2

inches greater than the water heater dimen­

sions and must be piped to an adequate drain. The pan must
not restrict combustion air flow. Under no circumstances is the
manufocturer or Sears to be held liable for any water dam^
in connection with this water heater.

AWARNING

INSTALLATIONS IN AREAS WHERE FLAMMABLE UQUIDS
(VAPORS) ARE LIKELY TO BE PRESENT OR STORED
(GARAGES,

STORAGE,

AND

UTILITY

AREAS,

ETC);

Flammable liquids (such as gasoline, solvents, propane (LP) or

butane, etc.), all of which emit flammable vapors, may be
improperly stored or used in such areas. The gas water heater
pilot light or main burner can ignite such vapors. The resulting
flatiiback and lire can cause death or serious bums to anyone in
the area, as well as property damage.

If installation in such areas is your only option, then the installa­

tion must be accomplished in a way that the pilot flame and

main burner flame are elevated from the floor at least ISinches.

While this may reduce the chances of flammable vapors from a
floor spill being ignited, gasoline and other flammable substances

should never be stored or used in the same room or area con­
taining a gas water heater or other open flame or spark produc­
ing appliance.
NOTE: Flammable vapors may be drawn by air currents from

other areas of the structure to the appliance.

AWARNING

Propellants of aerosol sprays and volatile compounds, (clean­

ers, chlorine based chemicals, refrigerants, etc.) in addition to

being highly flammable in many cases, will also change to cor­
rosive hydrochloric acid when exposed to the combustion

products of the water heater. The results can be hazardous,

and also cause product friilure.

The location selection must provide adequate clearances for ser­

vicing and proper operation of the water neater.

AWARNING

This water heater must not be installed directly on carpeting.
Carpeting must be protected by a metal or wood panel

beneath the appliance extending beyond the full width and
depth of the appliance by at least 3 inches (76.2mm) in any
direction, or if the appliance is installed in an akove or closet,
the entire floor must be covered by the panel. Failure to heed
this warning may result in a fire haziud.

AWARNING

Minimum clearances between the water heater and com­
bustible construction are I" at the sides and rear, 4" at the

front, and 6" from the vent pipe. Clearance from the top of the
jack^ is 18" on most models. Note thata lesser dimension may

be allowed on some models. Refer to the label on the water
heater adjacent to the gas control valve for all clearances.

MAX.

VENTIIATION

AIR

OPENINGS

12' MAX.

r MIN.

TOP VIEW

WITHcSiPê&iR Ofcì&SET

WITH DOOR

I ' M N .

MIN.

r MIN.

Figure I

1 RECTANGULAR
1 AIR DUCT

MIN

AIR DUCT

AWARNING

A gas water heater cannot operate properly without the cor­

rect amount of air for combtstion. Do not install in a confined
area such a doset, unless you provide air as shown in the '‘Facts
to Consider About the Location" section. Never obstruct the
flow of ventilation air. If you have any doubts or questions at all,
call your gas company, fêlure to provide the proper amount of
combustion air can result in a fire or eaqilosion and can cause

DEATH, SERIOUS BODILY INJURY, OR PROPERffY DAMAGE.

AWARNING

If this water heater will be used in beauty shops, barber shops,
cleaning establishments, or self-service laundries with dry
deaning equipment, it is imperative that the water heater or
water heaters be installed so that combustion and ventilation
air be taken from outside these areas. Refer to the "Facts to
Consider About the Location" section of this manual and also
the latest edition of the National Fuel Gas Code, ANSI Z223.I,
also referred to as NFPA 54 for specifics provided concerning
air required.