beautypg.com

Awarning, Safety precautions – Kenmore POWER MISER 153.336951 User Manual

Page 2

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Safety Precautions

AWARNING

Ir^pnipeil

instdlation,

adjustment,

alteration,

service

or

niain^enancd

cap

cause

DEATH,

SERIOUS

BODILY

injury

,

or

property

damage

.

Refer

to

this

manu­

al

fori

as^stance'or

consult

your

local

Sears

Service

Cbnter for further information.

T

t Г

AWARNING

WATER

HEATERS

EQUIPPED

FOR

ONE

TYPE

GAS

ONLY: This water heater is equipped for one type gas
oniy. Check the model rating plate near the gas control
valve for the correct gas. DO NOT USE THIS WATER

HEATER

WITH

ANY

GAS

OTHER

THAN

THE

ONE

SHOWN ON THE MODEL RATING PLATE. Failure to
use the correct gas can cause problems which can result in
DEATH,

SERIOUS

BODILY

INJURY,

OR

PROPERTY

DAMAGE. If you have any questions or doubts consult
your gas supplier or local utility.

AWARNING

INSTALLATIONS

IN

AREAS

WHERE

FLAMMABLE

LIQ­

UIDS

(VAPORS)

ARE

LIKELY

TO

BE

PRESENT

OR

STORED

(GARAGES,

STORAGE,

AND

UTILITY

AREAS,

ETC):

Flammable

liquids

(such

as

gasoline,

solvents,

propane (LP) or butane, etc.), all of which emit flammable
vapors, may be improperly stored or used in such areas.
The gas water heater pilot light or main burner can ignite
such vapors. The resulting flashback and fire can cause
death or serious bums to anyone in the area, as well as
property damage.

If installation in such areas is your only option, then the

installation must be accomplished in a way that the pilot
flame and main burner flame are elevated from the floor
at least 18 inches. While this may reduce the chances of
flammable vapors from a floor spill being ignited, gasoline

and other flammable substances should never be stored or
used in the same room or area containing a gas water
heater or other open flame or spark producing appliance.
NOTE: Flammable vapors may be drawn by air currents
from other areas of the structure to the appliance.

AWARNING

If this water heater will be used in beauty shops, barber
shops,

cleaning

establishments,

or

self-service

laundries

with dry cleaning equipment, it is imperative that the
water heater or water heaters be installed so that com­
bustion and ventilation air foe taken from outside these

areas. Refer to the "Locating The New Water Heater"
section of this manual and also the latest edition of the
Nationai Fuel Gas Code, ANSI Z223.I, also referred to as
N F PA 54 for specifics provided concerning air required.

AWARNING

A fire can start if combustible materials such as clothing,
cieaning materials, or flammable liquids are placed against
or next to the water heater.

AW^NING

At the time of manufacture this water heater was pro­

vided

with

a

combination

temperature-pressures

relief

valve certified by a nationally recognized testing labora­
tory that maintains periodic inspection of production of

listed equipment or materials, as meeting the require­
ments

for

Relief

Valves

and

Automatic

Gas

Shutoff

Devices for Hot Water Supply Systems, and the latest
edition of ANSI Z2I.22 and the code requirements of

ASME. If replaced, the valve must meet the require­

ments of local codes, but not less than a combination
temperature and pressure relief valve certified as meet­
ing the requirements for Relief Valves and Automatic

Gas

Shutoff Devices for Hot Water Supply Systems,

ANSI Z21.22 by a nationally recognized testing laborato­

ry that maintains periodic inspection of production of
listed equipment or materials.
The valve must be marked with a maximum set pressure

not to exceed the marked hydrostatic working pressure
of the water heater (150 lbs./sq. in.) and a discharge
capacity not less than the water heater input rate as
shown on the model rating plate. (Electric heaters -
watts divided by 1000 x 3415 equal BTU/Hr. rate.)

Your local jurisdictional authority, while mandating the
use of a temperature-pressure relief valve complying

with ANSI Z2I.22 and ASME, may require a valve model

different from the one furnished with die water heater.
Compliance with such local requirements must be satis­
fied by the installer or end user of the water heater with

a locally prescribed temperature-pressure relief valve

installed in the designated opening in the water heater in
place of the frctory furnished valve.

For safe operation of the water heater, the relief valve
must not be removed from it’s designated opening or
plugged.
The temperature-pressure relief valve must be installed

directly into the fitting of the water heater designated for
the relief valve. Position tiie valve downward and provide
tubing so that any discharge will exit only within 6 inches
above, or at any distance below the structural floor. Be
certain that no contact is made with any live electrical

part. The discharge opening must not be blocked or
reduced

in

size

under

any

circumstances.

Excessive

length, over 30 feet, or use of more than four elbows can
cause restriction and reduce the discharge capacity of
the valve.

No valve or other obstruction is to be placed between

the relief valve and the tank. Do not connect tubing

directly to discharge drain unless a 6" air gap is provided.

To prevent bodily injury, hazard to life, or property dam­
age, the relief valve must be idlowed to discharge water

in quantities should circumstances demand. If the dis­
charge pipe is not connected to a drain or other suitable

means, the water flow may cause property damage.

The Discharge Pipe:

• Must not be smaller in size than the outlet pipe size of

the valve, or have any reducing couplings or other
restrictions.

• Must not be plugged or blocked.
• Must be of material listed for hot water distribution.

Must be installed so as to allow complete drainage of

both

the

temperature-pressure

relief

valve,

and

the

discharge pipe.

• Must terminate at an adequate drain.

• Must not have any valve between the relief valve and

tank.