Awarning, Safety precautions – Kenmore POWER MISER 153.336951 User Manual
Page 2
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Safety Precautions
AWARNING
Ir^pnipeil
instdlation,
adjustment,
alteration,
service
or
niain^enancd
cap
cause
DEATH,
SERIOUS
BODILY
injury
,
or
property
damage
.
Refer
to
this
manu
al
fori
as^stance'or
consult
your
local
Sears
Service
Cbnter for further information.
T
t Г
AWARNING
WATER
HEATERS
EQUIPPED
FOR
ONE
TYPE
GAS
ONLY: This water heater is equipped for one type gas
oniy. Check the model rating plate near the gas control
valve for the correct gas. DO NOT USE THIS WATER
HEATER
WITH
ANY
GAS
OTHER
THAN
THE
ONE
SHOWN ON THE MODEL RATING PLATE. Failure to
use the correct gas can cause problems which can result in
DEATH,
SERIOUS
BODILY
INJURY,
OR
PROPERTY
DAMAGE. If you have any questions or doubts consult
your gas supplier or local utility.
AWARNING
INSTALLATIONS
IN
AREAS
WHERE
FLAMMABLE
LIQ
UIDS
(VAPORS)
ARE
LIKELY
TO
BE
PRESENT
OR
STORED
(GARAGES,
STORAGE,
AND
UTILITY
AREAS,
ETC):
Flammable
liquids
(such
as
gasoline,
solvents,
propane (LP) or butane, etc.), all of which emit flammable
vapors, may be improperly stored or used in such areas.
The gas water heater pilot light or main burner can ignite
such vapors. The resulting flashback and fire can cause
death or serious bums to anyone in the area, as well as
property damage.
If installation in such areas is your only option, then the
installation must be accomplished in a way that the pilot
flame and main burner flame are elevated from the floor
at least 18 inches. While this may reduce the chances of
flammable vapors from a floor spill being ignited, gasoline
and other flammable substances should never be stored or
used in the same room or area containing a gas water
heater or other open flame or spark producing appliance.
NOTE: Flammable vapors may be drawn by air currents
from other areas of the structure to the appliance.
AWARNING
If this water heater will be used in beauty shops, barber
shops,
cleaning
establishments,
or
self-service
laundries
with dry cleaning equipment, it is imperative that the
water heater or water heaters be installed so that com
bustion and ventilation air foe taken from outside these
areas. Refer to the "Locating The New Water Heater"
section of this manual and also the latest edition of the
Nationai Fuel Gas Code, ANSI Z223.I, also referred to as
N F PA 54 for specifics provided concerning air required.
AWARNING
A fire can start if combustible materials such as clothing,
cieaning materials, or flammable liquids are placed against
or next to the water heater.
AW^NING
At the time of manufacture this water heater was pro
vided
with
a
combination
temperature-pressures
relief
valve certified by a nationally recognized testing labora
tory that maintains periodic inspection of production of
listed equipment or materials, as meeting the require
ments
for
Relief
Valves
and
Automatic
Gas
Shutoff
Devices for Hot Water Supply Systems, and the latest
edition of ANSI Z2I.22 and the code requirements of
ASME. If replaced, the valve must meet the require
ments of local codes, but not less than a combination
temperature and pressure relief valve certified as meet
ing the requirements for Relief Valves and Automatic
Gas
Shutoff Devices for Hot Water Supply Systems,
ANSI Z21.22 by a nationally recognized testing laborato
ry that maintains periodic inspection of production of
listed equipment or materials.
The valve must be marked with a maximum set pressure
not to exceed the marked hydrostatic working pressure
of the water heater (150 lbs./sq. in.) and a discharge
capacity not less than the water heater input rate as
shown on the model rating plate. (Electric heaters -
watts divided by 1000 x 3415 equal BTU/Hr. rate.)
Your local jurisdictional authority, while mandating the
use of a temperature-pressure relief valve complying
with ANSI Z2I.22 and ASME, may require a valve model
different from the one furnished with die water heater.
Compliance with such local requirements must be satis
fied by the installer or end user of the water heater with
a locally prescribed temperature-pressure relief valve
installed in the designated opening in the water heater in
place of the frctory furnished valve.
For safe operation of the water heater, the relief valve
must not be removed from it’s designated opening or
plugged.
The temperature-pressure relief valve must be installed
directly into the fitting of the water heater designated for
the relief valve. Position tiie valve downward and provide
tubing so that any discharge will exit only within 6 inches
above, or at any distance below the structural floor. Be
certain that no contact is made with any live electrical
part. The discharge opening must not be blocked or
reduced
in
size
under
any
circumstances.
Excessive
length, over 30 feet, or use of more than four elbows can
cause restriction and reduce the discharge capacity of
the valve.
No valve or other obstruction is to be placed between
the relief valve and the tank. Do not connect tubing
directly to discharge drain unless a 6" air gap is provided.
To prevent bodily injury, hazard to life, or property dam
age, the relief valve must be idlowed to discharge water
in quantities should circumstances demand. If the dis
charge pipe is not connected to a drain or other suitable
means, the water flow may cause property damage.
The Discharge Pipe:
• Must not be smaller in size than the outlet pipe size of
the valve, or have any reducing couplings or other
restrictions.
• Must not be plugged or blocked.
• Must be of material listed for hot water distribution.
•
Must be installed so as to allow complete drainage of
both
the
temperature-pressure
relief
valve,
and
the
discharge pipe.
• Must terminate at an adequate drain.
• Must not have any valve between the relief valve and
tank.