PRODUCT DATA SHEETS
Base Grille Water Filtration System Model WF-NLC250/NLC250
Tested and certified by NSF Internationa! against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.
Capacity;
250 Gallons (946 Liters)
Service Flow Rate:
0.5 GPM (1
.89
L/min.)
@
60 psi.
Substance Reduction
U.S. ERA
Average
Maximum
Average
Minimum %
Average %
NSF Test
Aesthetic Effects
MCL
Influent
Effluent
Effluent
Reduction
Reduction
Number
Chlorine Taste/Odor
N/A
1.9 mg/L
N/A
0.04 mg/L
N/A
97.9%
994707
Particulate
N/A
610,000/mL*
N/A
154/mL
N/A
99.97%
994711
Contaminant
U.S. ERA
Average
Maximum
Average
Minimum %
Average %
NSF Test
Reduction
MCL
Influent
Effluent
Effluent
Reduction
Reduction
Number
Cyst
99.95%“
89,250/mL*
6/mL
2.3/mL
99.993%
99.997%
994710
Turbidity
0.5 NTU
29 NTU
0.1 NTU
0.09 NTU
99.5%
99.69%
994710
Lead: @ pH 6.5
0.015 mg/L
0.16 mg/L“*
0.001 mg/L
0.001 mg/L
99.4%
99.4%
994708
Lead:
@
pH 8.5
0.015 mg/L
0.16 mg/L*“
0.002 mg/L
0.001 mg/L
98.8%
99.4%
994709
Base Grille Water Filtration System Model WF-LC400/LC400
Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.
Capacity: 400
Gallons
(1514
Liters)
Service Flow Rate: 0.5
GPM
(1.89 L/min.) <
( 60 psi.
Substance Reduction
U.S. ERA
Average
Maximum
Average
Minimum %
Average %
NSF Test
Aesthetic Effects
MCL
Influent
Effluent
Effluent
Reduction
Reduction
Number
Chlorine Taste/Odor
N/A
2.0 mg/L
N/A
0.04 mg/L
N/A
98%
994707
Particulate
N/A
610,000/mL*
N/A
154/mL
N/A
99%
994711
Contaminant
U.S. ERA
Average
Maximum
Average
Minimum %
Average %
NSF Test
Reduction
MCL
Influent
Effluent
Effluent
Reduction
Reduction
Number
Cyst
99.95%“
89,250/mL*
6/mL
2.3/mL
99.993%
99.997%
994710
Turbidity
0.5 NTU
29 NTU
0.12 NTU
0.09 NTU
99.59%
99.69%
994710
Lead: @ pH 6.5
0.015 mg/L
0.16 mg/L*“
0.001 mg/L
0.001 mg/L
99.4%
99.4%
994708
Lead:
@
pH 8.5
0.015 mg/L
0.16 mg/L*“
0.002 mg/L
0.001 mg/L
98.8%
99.4%
994709
■ Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
City or Well
Water Pressure
30- 120 psi (207 - 827 kPa)
Water Temperature
OS'* -100°F (O.e” - ST.S” C)
■
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
■ Model WF-NLC250
Change cartridge at least every 6-9
months. Use replacement cartridge NLC 250, part# 9902.
2000 suggested retail price of $39.95 U.S.A./S49.95 Canada.
■ Model WF-LC400
The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter’s rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter’s rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge LC400, part#
9902. 2000 suggested retail price of $39.95 U.S.A./$49.95
Canada.
■
The product is for cold water use only.
■
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
■
Refer to the “Assistance or Service” section for the
Manufacturer’s name, address and telephone number.
‘Test requirement is at least 100,000 particles/ml of AC Fine Test Dust. “Cyst performance is
%
reduction based on NSF Standard 53. ‘“Test
requirement is 0.15 mg/L ± 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
® NSF is a registered trademark of NSF International.