■ Periscope Installation (For use with dryer vent to wall vent

mismatch):

Part Number 26-49901 - Less than 5" (12.7 cm) mismatch

Part Number 26-49908 - 5" (12.7 cm) to 18" (45.72 cm)

mismatch

Part Number 26-49904 - 18" (45.72 cm) to 29" (73.66 cm)

mismatch

Part Number 26-49905 - 29" (73.66 cm) to 50" (127 cm)

mismatch

Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible

portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.

The angled hood style (shown following) is acceptable.

Determine Vent Length
1. Select the route that will provide the straightest and most

direct path outdoors. Plan the installation to use the fewest

number of elbows and turns. When using elbows or making

turns, allow as much room as possible. Bend vent gradually
to avoid kinking. Avoid 90° turns when possible.

better

2. Determine vent length

The maximum length of the exhaust system depends upon:

■ The type of vent (rigid metal or flexible metal).

■ The number of elbows used.

■ Type of hood.

Recommended hood styles are shown here.

^

2

V

2

"

(6.4 cm)

See the exhaust vent length chart that matches your hood

type for the maximum vent lengths you can use.

Exhaust systems longer than specified will:

■ Shorten the life of the dryer.

■ Reduce performance, resulting in longer drying times and

increased energy usage.

3. Determine the number of elbows you will need.

IMPORTANT: Do not use vent runs longer than specified in

the Vent Length Chart.

The following chart helps you determine your maximum vent

length based on the number of 90° turns or elbows you will
need and the type of vent (rigid or flexible metal) and hood

that you will use.

Vent Length Chart

Number of

90° turns

or elbows

Type of
vent

Box or
Louvered

hoods

Angled

hoods

0

Rigid metal
Flexible metal

64 ft (20 m)
36 ft (11 m)

58 ft (17.7 m)
28 ft (8.5 m)

1

Rigid metal
Flexible metal

54 ft (16.5 m)
31 ft (9.4 m)

48 ft (14.6 m)
23 ft (7 m)

2

Rigid metal
Flexible metal

44 ft (13.4 m)
27 ft (8.2 m)

38 ft (11

.6

m)

19 ft (5.8 m)

3

Rigid metal
Flexible metal

35 ft (10.7 m)
25 ft (7.6 m)

29 ft (

8.8

m)

17 ft (5.2 m)

4

Rigid metal
Flexible metal

27 ft (8.2 m)
23 ft (7 m)

21 ft (6.4 m)
15 ft (4.6 m)

NOTE: Side and bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length, add one
90° turn to the chart.

Iriitaii

Mm

itSysfern

A. Louvered hood style
B. Box hood style

1. (Optional) Put on safety glasses and gloves.

2. Install exhaust hood. Use caulking compound to seal exterior

wall opening around exhaust hood.

3. Connect vent to exhaust hood. Vent must fit inside exhaust

hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.

4. Run vent to dryer location. Use the straightest path possible.

See “Determine Vent Length.” Avoid 90° turns. Use clamps to
seal all joints. Do not use duct tape, screws or other fastening
devices that extend into the interior of the vent to secure

vent.