BELT OR BRUSHROLL REMOVAL AND REPLACEMENT
A
WARNING
Electrical Shock and Personal
Injury Hazard
Disconnect electrical supply
before servicing or cleaning
the unit. Failure to do so could
result in electrical shock or
personal injury from vacuum
cleaner suddenly starting.
TO REMOVE BELT
Lay cleaner flat and flip cleaner to expose
nozzle base. To remove nozzle guard, slide
Jock A to unlock position, to the left. Then
depress lock B to unlock nozzle guard.
Rotate/pivot the
nozzle guard and
pull off
® Lift and remove
brushroil. Dispose
of old belt.
TO REPLACE BELT
OR BRUSHROLL
Slide belt onto motor
shaft.
Place new belt in area
of brushroil without
bristles.
With new belt in place,
pull and slide brushroil
into nozzle making
sure that the brushroil
end caps are in the
correct orientation (see
diagram for end cap
orientation). Rotate
brushroil manually
to make sure belt is
properly aligned.
Secure by aligning
the three (3) tabs
in the base slots.
To reattach nozzle
guard, rotate/pivot
back Into position.
To secure nozzle
guard, push lock B
down to lock position.
Slide lock A into lock
position, to the right.