beautypg.com

Kenmore PLASMAWAVE 85450 User Manual

Page 10

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

True HEPA Filter Replacement

1. Turn off the air cleaner and unplug the

electrical cord.

2. Remove the front panel by pulling gently

from the lower portion of the panel. Do

not force, the panel should remove easily.

3. Remove the Carbon Pre-Filter and

plastic frame by gently pulling out from

the bottom and down from the top,

4. Remove the True HEPA Filter and

dispose of if.

5- Remove the plastic wrap from the new

True HEPA Filler and insert it with the

arrow showing “air flow” pointing in

toward the back of the air cleaner. The

white labs at the top and bottom of the

True HEPA Filler will point out to the front

of the unit.

6. Reinstall the plastic frame and Carbon

Pre-Filter by inserting tabs up into the air

cleaner and gently pushing in at the
bottom fab uni the frame fits into place
snuggly.

7. Replace the front panel by hooking the

panel on the top of the unit. Swing the
panel in by pushing gently on each side

of the unit and then lock it into place.

8. Plug In air cleaner and press POWER

button until short “beep" sounds.

9. Press the RESET FILTER button by

gently inserting a paperclip into the

RESET FILTER hole on the control
panel. The light will flash 5 times before

a “beep” sounds to indicate the filter has

been reset. See figure C on page 8 or
Dtag. 9 to the right.

The air cleaner will take 3-4 minutes to
calibrate Bie AIR QUALITY sensor. During
this time the sensor lights will flash on

and off. Once the sensor has calibrated,

the lights will stop flashing and the unit
will begin In AUTO mode.

11

This manual is related to the following products: