3 - valve – Kenmore 625.3486 User Manual
Page 19
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
![background image](/manuals/665573/19/background.png)
SECTION 4
OTHER THINGS TO KNOW
4A.
DIMENSIONS/SPECIFICATIONS
FIG. 12
BYPASS VALVES
Bypass valve(s) should always remain in soft
water service position. Position in "bypass"
only it needed for softener repairs.
SINGLE
PULL
OUT
for service
PUSH
IN
for
bypass
3 - VALVE
FOR SERVICE
close bypass valve
open Inlet & outlet valves outlet
FOR BYPASS
Lvi
open bypass valve
close Inlet & outlet valves
Bypass
Valve
Inlet
Valve
V 1
f
INCHES
CM
A
Salt Tank Height
40-1/4
102.2
B
Resin Tank Diameter (nominai)
9
22.7
C
Resin Tank Height (nominai)
40
101.6
D
Iniet-Outiet Height
41-1/2
105.4
E
Overaii Height
47
119.4
F1 Length
19-1/2
49.5
F2 Width
16-1/2
41.9
—
Distance between iniet-outiet
center iines
3-7/8
9.8
MODEL NO. 625.348600
TIMER HF CODE HF31
NOTE: Please see the rating decal for water softener operating capacity, salt usage and service flow rate/
pressure loss performance specifications. Performance specifications are validated by the Water Quality
Association (WQA). The rating decal is located on the rim, under the salt hole cover (see page 28).
WATER SUPPLY TO WATER SOFTENER
MINIMUM WATER SYSTEM FLOW (gpm) ........................................ 3
MINIMUM-MAXIMUM WATER PRESSURE (psi) ..................... 20-120
MAXIMUM WATER TEMPERATURE (°F) ..................................... 120
MAXIMUM WATER HARDNESS (gpg)........................................... 110
MAXMUM “CLEAR WATER” IRON (ppm) ..........................................7
SALT FOR WATER SOFTENER
TYPE OF SALT NEEDED............................................... Nugget/Pellet
ALTERNATE TYPE OF SALT .. Pure, evaporated, compacted
water softener salt
STORAGE CAPACITY (pounds)..................................................... 200
OTHERS
TYPE OF ION EXCHANGE MATERIAL (resin) High Capacity
AMOUNT OF RESIN (cu.ft.)............................................................. 1.0
REGENERATION (RECHARGE) CYCLE TIME (mln.)
FILL ....................................................................................... 3 - 1 3
BRINING/BR. RINSE..................................................................120
BACKWASH .................................................................................. 7
FAST RINSE...................................................................................3
TOTAL REGENERATION TIME
®........................ 1 3 3 - 1 4 3
gpm = gallons per minute psI = pounds per square Inch
gpg = grains per gallon
ppm = parts per million
® Does not Include CLEAN feature cycle times If set to ON.