beautypg.com

Performance data sheet, Application guidelines/water supply parameters, Base grille water filtration system – Kenmore WIOI67097A User Manual

Page 22

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

PERFORMANCE DATA SHEET

Base Grille Water Filtration System

Model T1KB1/T1RFKB1 Capacity 100 Gallons (379 Liters)

System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of
Chlorine Taste and Odor, Particuiate Class I*; and against NSF/ANSI Standard 53 for the reduction of

Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity, Asbestos, Lindane,

Tetrachioroethylene, Endrin, Alachlor, Chlorobenzene, Ethylbenzene, TTHM, MTBE and VOC.

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The

concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for wafer leaving the system, as specified in NSF/ANSI Standards 42 and 53.

Substance Reduction

Aesthetic Effects

NSF Reduction
Requirements

Average

Infiuent

Influent Challenge
Concentration

Maximum
Effluent

Average

Effluent

Minimum %

Reduction

Average %

Reduction

Chlorine Taste/Odor
Particulate Class 1*

50% reduction
85% reduction

2.0 mg/L
3533333#/mL

2.0 mg/L± 10%
At least 10,000 particles/mL

0.08 mg/L
22000 #/mL’“*

2.0 mg/L

11567 #/mL

95.93
99.38

97.36
99.67

Contaminant
Reduction

NSF Reduction
Requirements

Average

Infiuent

Influent Challenge
Concentration

Maximum
Effluent

Average

Effluent

Minimum %

Reduction

Average %

Reduction

Lead: @ pH 6.5
Lead: @ pH 8.5

0.010 mg/L
0.010 mg/L

150 ug/L
157 ug/L

0.15 mg/L ± 10%
0.15 mg/L ± 10%

1.0 ug/L

2.0 ug/L

1 ug/L
1.08 ug/L

99.33
98.72

99.33
99.31

Mercury: @ pH 6.5
Mercury: @ pH 8.5

0.002 mg/L
0.002 mg/L

0.0058 mg/L
0.0057 mg/L

0.006 mg/L ± 10%
0.006 mg/L ± 10%

0.0002 mg/L
0.0002 mg/L

0.0002 mg/L
0.0002 mg/L

96.53
96.5

96.53
96.5

Benzene

0.005 mg/L

15 ug/L

0.015 mg/L± 10%

0.5 ug/L

0.5 ug/L

96.67

96.67

O-Dichlorobenzene

0.6 mg/L

1750 ug/L

1.8 ± 10%

1.0 ug/L

1.0 ug/L

99.94

99.94

Toxaphene

0.003 mg/L

15 ug/L

0.015 ± 10%

1.0 ug/L

1.0 ug/L

93.33

93.33

Atrazine

0.003 mg/L

10 ug/L

0.009 mg/L± 10%

2 ug/L

2 ug/L

80.8

80.8

Asbestos

99%

101 MFL

10^to 10“fibers/L**

0.17 MFL

0.17 MFL

99.83

99.83

Live Cysts*

Turbidity

>99.95%
0.5 NTU

120,000/L
11.4 NTU

50,000/L min.
11 ± 1 NTU

8/L*
0.41 NTU

1/L*
0.24 NTU

99.99
96.4

>99.99
97.89

Alachlor

0.002 mg/L

41.3 ug/L

0.04 ± 10%

0.2 ug/L

0.2 ug/L

99.52

99.52

Endrin

0.002 mg/L

5.9 ug/L

0.006 ± 10%

0.5 ug/L

0.3 ug/L

91.5

95.47

Ethylbenzene

0.7 mg/L

1867 ug/L

2.1 ± 10%

0.70 ug/L

0.0588 ug/L

99.96

100

Lindane

0.002 mg/L

1.9 ug/L

0.002 ± 1 0 %

0.02 ug/L

0.02 ug/L

98.93

98.93

Chlorobenzene

0.6 mg/L

2.0 ug/L

2.0 ± 10%

0.0005 ug/L

0.0005 ug/L

99.98

99.98

Tetrachioroethylene

0.005 mg/L

14.2 ug/L

0.015 ± 10%

0.5 ug/L

0.5 ug/L

96.47

96.47

TTHM

0.080 mg/L

465 ug/L

0.45 ± 20%

1.0 ug/L

0.5 ug/L

99.78

99.88

MTBE

0.005 mg/L

14 ug/L

0.015 ± 20%

0.70 ug/L

0.52 ug/L

94.94

96.27

VOC

0.015 mg/L

0.3520 mg/L

0.300 ± 1 0 %

0.0060 mg/L

0.0008 mg/L

98.4

99.78

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm
Temp. = 68“F to 71.6°F (20“C to 22°C).

It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.

■ Model T1KB1:

The filter monitor system measures the amount of

water that passes through the filter and alerts you to replace the
filter.

Style 1

- When the filter indicator reads 10%, order a new filter.

When the filter indicator reads 0%, it is recommended that you

replace the filter.

Style 2

- When the filter indicator light changes from green to

yellow, order a new filter. When the filter indicator light changes
from yellow to red, it is recommended that you replace the filter.

Use replacement cartridge T1RFKB1, part #9030. In Canada, use
replacement cartridge T1RFKB1, part #9030B. 2008 suggested
retail price of $41.99 U.S.A./$51.99 Canada. Prices are subject to
change without notice.

These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory

conditions, actual performance may vary.

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the

*Class I particle size: >0.5 to <1 urn

**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.

^Tibers greater than 10 um in length

♦Based on the use of Cryptosporidium parvum oocysts

® NSF is a registered trademark of NSF International.

(1.9 Lpm). Pressure = 60 psig (413.7 kPa).

system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.

Refer to the front cover or “Accessories” section for the
Manufacturer's name, address and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited

warranty.

Application Guidelines/Water Supply Parameters

City or Well
30- 120 psi (207 - 827 kPa)
33° - 100°F {0.6° - 37.8°C)
0.5 gpm (1.9 L/min) @ 60 psi

Water Supply
Water Pressure
Water Temperature
Service Flow Rate

22