BECKETT OIL BURNER. NOZZLE. AND AIR SETTINGS
BOILER
DELEVAN
FIRING
HEAD-ADJ.
LOW FIRE
AIR
STATIC
OIL
MODEL
OIL NOZZLE RATE (gph)
OR SETTING
BAFFLE
SHUTTER/BAND
PLATE
BURNER
3EW.65*
0.50-80°B
0.65
FO - 1 1/8
YES
10/0
3-5/8
AFG F-HEAD
3EW.75
0.65-70“B
0.75
F3 - 1 1/8
YES
10/0
3-1/2
AFG F-HEAD
3EW1.00
0.85-70“B
1.00
F3- 1 1/8
NO
10/2
3-1/2
AFG F-HEAD
4EW.90
0.75-80°A
0.90
F3 - 1 1/8
NO
8/0
3-1/2
AFG F-HEAD
4EW1.25
1.00-80°A
1.25
F6 - 1 1/8
NO
10/0
3-3/8
AFG F-HEAD
4EW1.50
1.25-80°A
1.50
F6 - 1 1/8
NO
10/2
3-3/8
AFG F-HEAD
5EW1.20
1.00-60°B
1.20
0
NO
10/1.5
2-3/4
AFG 50 MD
5EW1.75
1.50-45“B
1.75
2
NO
10/4
2-3/4
AFG 50 MD
5EW2.00
1.65-60-B
2.00
4
NO
10/5
2-3/4
AFG 50 MD
*To fire the SEW.65 on rate, the oil pressure must be increased to 175 psig.
All Beckett oil burners for the EW boiler are factory preset at 140 psig.
CARLIN OIL BURNER. NOZZLE. AND AIR SETTINGS
BOILER“
DELEVAN
FIRING
HEAD
AIR BAND
CARLIN
MODEL
OIL NOZZLE RATE (gph)
SETTING
SET POINT
BURNER*
3EW.65
0.55-70°B
0.65
0.50
0.52
EZ-1
HP
3EW.75
0.65-60°B
0.75
0.60 / 0.65
0.60
EZ-1 HP
3EW1.00
0.85-60°B
1.00
0.85/1.00
0.80
EZ-1 HP
4EW.90
0.75-60°B
0.90
0.75
0.75
EZ-1 HP
4EW1.25
1.00-60°B
1.25
0.85 /1.00
0.90
EZ-1 HP
4EW1.50
1.25-60°B
1.50
1.10/1.25
1.25
EZ-1 HP
5EW1.20
1.00-60°B
1.20
0.85/1.00
0.90
EZ-1 HP
5EW1.75
1.50-60°B
1.75
1.50
1.65
EZ-2 HP
5EW2.00
1.65-70°B
2.00
1.65/1.75
1.95
EZ-2 HP
'All Carlin EZ-1 HP and EZ-2 HP oil burners are factory preset at 150 psig.
RIELLO 40 OIL BURNER. NOZZLE. AND AIR SETTINGS
BOILER
DELEVAN
FIRING
TURBULATOR/AIR OIL PRESSURE
RIELLO 40
MODEL
OIL NOZZLE FÎATE (gph) SHUTTER SETTING
(PSIG)*
BURNER MODEL
3EW.65
0.50-70°W
0.65
0.5 / 2.0
155
F5
3EW.75
0.65-70°W
0.75
2.0 / 2.2
150
F5
3EW1.00
0.85-70°W
1.00
2.0 / 3.2
170
F5
4EW.90
0.75-70°W
0.90
1.5/2.6
160
F5
4EW1.25
1.00-70°W
1.25
2.5/3.8
170
F5
4EW1.50
1.25-70°W
1.50
4.0/7.0
175
F5
5EW1.20
1.00-70°W
1.20
2.5/3.5
150
F5
5EW1.75
1.50-70°W
1.75
2.0/3.8
155
F10
5EW2.00
i.zs-zo-w
2.00
2.5/4.1
155
F10
'All Riello 40 F5 and FI0 oil burners are factory preset at 145 psig.
NOTE: All burners use an insertion depth of 2-1/4" and fired at a
overfire draft of -0.02 inches w.c. The burner settings provided
are intended for initial start up only. Final adjustment must be made
using combustion test instruments.____________________________