Antifreeze added to boilers
must be non-toxic, and must be of a type specifically intended for use in closed
hydronic heating systems. Under no circumstances should automotive antifreeze be used. Antifreeze used
in any boiler may reduce capacity by 10% or more and increase fuel consumption. Tankless coil
performance will fall as concentration of antifreeze is increased. Refer to boiler and piping water volumes
tables in this manual.
BOILER WATER VOLUMES
PIPING WATER VOLUMES
Number of
Boiler Sections
Total Volume
(Gallons)
3
9.6
4
11.6
5
13.7
PIPE SIZE
COPPER PIPE
FACTOR
STEEL PIPE
FACTOR
82.5
63.5
%”
40.0
36.0
1”
23.3
22.2
1-1/4”
15.3
12.8
1-1/2”
10.8
9.5
2”
6.2
5.8
factor in table to determine volume in gallons.