Natural gas safety instructions – Kenmore 141.168600 User Manual
Page 14
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Installing LP Gas Fuel Gauge Assembly
Figure 10a
1. Unscrew the M18x1.5 and M8x1.25 nuts from
the Pressure Cylinder.
2. Unscrew and remove the Fixing Ring from the
Dial. See Fig. 10a.
3. Insert the end with Pressure Cylinder through
the notched hole on right Side Shelf. See
Fig. 10b. Turn the Dial until it matches the
notched hole, and push it into the hole.
4. Screw the Fixing Ring back to the Dial from
the Pressure Cylinder side. See Fig. 10c.
5. Insert the Pressure Cylinder into Pressure
Cylinder Guide, and secure using the de
tached M18x1.5 nut. See Fig. 11.
6. Attach Tank Hook to the lower thread of
Pressure Cylinder, and secure firmly using the
detached M8x1.25 nut. Once tank is con
nected, the dial will indicate amount of gas
in tank.
Natural Gas Safety Instructions
Your natural gas grill is designed to operate on
natural gas only, at a pressure of
T water column
(W.C.) {1/4 psig or 1.75 kpa), regulated at the
residential meter. Check with your gas utility
company for local gas pressure and with your
local municipality for building code requirements.
If your residential gas line pressure has not been
regulated to
T W.C., contact your local gas utility
company for professional assistance.
It is recommended that a Shutoff Valve be installed
at the gas supply source outdoors. Install at a point
after the gas pipe exits the outside wall and before
the quick-disconnect hose, or install it at the point
before the gas fine piping enters the ground.
Pipe sealing compound or pipe thread tape
resistant to the action of natural gas must be
used on all male pipe threads when making the
connection.
Disconnect your gas grill from fuel source when
the gas supply is being tested at high pressures.
This gas grill and its individual shutoff valve must
be disconnected from the gas supply pipe system
during any pressure tesiting of that system at
pressure in excess of 1/2 psi (3.5kpa).
Turn off your gas grill when the gas supply is
being tested at low pressures. The grill must be
isolated from the gas supply pipe system by
closing its individual manual shutoff valve during
any pressure testing of the gas supply pipe
system at pressures equal to or less than 1/2 psi
(3.5kpa).
Figure 10b
Figure 10c
CYLINDER
Figure 11
14