Water piping, Water piping ,10, Warning – Kenmore POWER MISER 153.320661 User Manual
Page 9: Cautio, Adanger
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

A
WARNING
Fire Hazard / Electric Shock Hazard
è
• Do not use this water heater with
any voltage otherthan shown on the
model rating plate.
• Failure to use the correct voltage
shown on the model rating plate
could result in death, serious bodily
injury, or property damage.
Before making
the
conversion
to
5500 watts,
check the
(1)
power suppiy ,
. . must
be 240 volts, (2) wiring . . . 10 gauge
AWG @
Type
TW,
60°C or equivalent, and (3) Circuit breakers
or fusing
. . .capabie
of 30 amp loading. Also, the installation
must conform
with
this manual, local
codes
and electric utility
rules. Failure to comply can result in DEATH, SERIOUS BODILY
INJURY OR PROPERTY DAMAGE.
ELECTRIC
WATER
HEATER
MODEL NUMBER
CAPACITY
U.S. GAL.
LISTED
9$2M
SERIAL NU[\iBER
FACTORY EQUIPPED WITH
UPPER LOWER
ELEMENT ELEMENT MAXIMUM VOLTS
WATTS WATTS WATTS A.C. ONLY
MAXIMUM
CHECK HERE WORKING
IF INSTALLED AS PRESSURE
FACTORY EQUIPPED P.S.I.
OPTIONAL WATTAGE
UPPER LOWER
ELEMENT ELEMENT MAXIMUM
WATTS WATTS WATTS
CHECK
HERE
IF CONVERTED
WARNING
SEE CONVERSION
INSTRUCTION
NOTE: Whether or not the
element
conversion
is made
the
model rating plate must be
marked.
Using a hard point ink
pen, check the appropriate block within the model rating plate,
which is located adjacent to
the
lower access panel.
Water Piping
ADANGER
Water
temperature
over 125“F
(52°C) can cause severe burns
instantly resulting in severe injury
or death.
Children, the elderly, and the
physically or mentally disabled
are at highest riskfor scald injury.
Feel water before bathing or
showering.
Temperature limiting valves are
available.
Read instruction manual for safe
temperature setting.
HOTTER WATER CAN SCALD; Wafer heaters are intended to
produce hot water. Water heated to a temperature which will
satisfy clothes washing, dish
washing,
and other sanitizing
needs
can scald and
permanently
injure you upon contact.
Some people are
more
likely to be permanently injured by hot
water
than
others. These include the
elderly,
children,
the infirm,
or physically/mentally handicapped. If anyone
using
hot
wafer
in your home fits info one
of these
groups or
If
there is a
local
code or state law requiring a certain temperature water at the
hot water tap, then you must take special precautions. In
addition to using the lowest possible temperature setting that
satisfies your
hot water
needs,
a means such as a mixing
valve,
shall
be used
at
the
hot
wafer taps used by these people
or at
the
water heater.
Mixing
valves are
available
at plumbing
supply or
hardware
stores. Follow
manufacturers
instructions
for
installation
of the valves. Before changing the factory
setting
on the thermostat, read the “Temperature Regulation” section
in
this
manual.
FIGURES.
Figure 9 shows the attachment of the water piping to the water
heater.
The
water
heater is equipped with 3/4” water
connections.
If a water heater is installed in a closed wafer supply system;
such as
one
having a back-flow preventer, check valve,
wafer
meter with a check valve, etc... in the cold water supply; means
must
be
provided
to
control thermal expansion. Contact the
local utility
or Sears Service Center on how to
control
this
situation.
NOTE: ¡f using copper tubing, solder tubing to an adapter
before attaching the adapter to the water inlet connection.
Do not solder the water supply lines directly to the cold water
inlet, it will harm the dip tube and damage the tank.
CAUTIO
I
Property Damage Hazard
> Avoid water heater damage.
' Install thermal expansion tank if necessary.
• Do not apply heat to cold water inlet.
■ Contact qualified installer orsen/ice agency.