LIFT OUT TAB TO UNCLIP
TERMINAL COVER FROM
THERMOSTAT
Tighten
terminals 2 and 3 to ensure proper
electricai
connection.
5,
FIGURE 16.
Remove the
screws from terminal 2 of
the element,
and
move
the looped
end
of the wire
aside.
FIGURE 17.
The buss bar is
labeled
5500 W. Place the buss bar over
terminals 2
and
3 with the 5500 W visible. Install the extra
screw provided into terminal 3.
AWARNING
Fire and Explosion Hazard
Failure to tighten screws can
cause afire.
Failure to do this could result in
death, serious bodily injury, or
property damage.
Failure to tighten
terminal screws
can cause a fire which
can
result in DEATH,
SERIOUS BODILY
INJURY, OR PROPERTY
DAMAGE,
9. Replace terminal
cover on
thermostat making
sure that
the locking tabs on
the
terminal cover are in place.
AWARNING
Fire and Explosion Hazard
Thermostat
must
be
flush
against the tank.
Make sure terminal cover is in
place
and
the
insulation
replaced.
Failure to do this could result in
death, serious bodily injury, or
property damage.
7. The
wire
removed from terminal 2 has a looped end.
It
must remain looped and
now
be placed (as
shown)
on
top
of
the buss bar,
over
the
opening
of
terminal 2,
and
secured using
the remaining screw.
Make
sure the
thermostat
is flush against the tank, the
terminal
cover is in place, and the
insulation
is replaced. Failure to do
so
can result
in DEATH, SERIOUS BODILY INJURY, OR
PROPERTY DAMAGE,
10. Replace the insulation
cap
with
handle back in place so
that it completely covers
the
thermostat and element.
FIGURE 19.
13