Installation
Receptacle Wiring
Receptacle wiring must be of adequate size for unit.
Refer to unit identification plate for exact power
requirements. Power requirements can also be
determined by the type of plug on unit. See Table 1 on
preceding page. Minimum size of wiring, based on
power requirements, is:
Units up to 20 amps:
12 gauge
20-30 amp units; 10 gauge
Use copper wire only. It is owner’s responsibility to
provide proper and adequate receptacle wiring that
conforms to alt applicable codes. All wiring should be
installed by a qualified electrician.
Window installation—^7000 and 9000 Btu
Units (Models 78079,70089)______________
CAUTION
To avoid risk of personal injury, property damage, or
product damage due to weight of device and sharp
edges that may be exposed:
■ Air conditioners covered in this manual pose an
excessive weight hazard. Two or more people are
needed to move and install unit. To prevent injury
or strain, use proper lifting and carrying methods.
■ Carefully inspect location where air conditioner
will be installed. Be sure it will support weight of
unit for extended period of time.
• Handle air conditioner with care. Wear protective
gloves whenever lifting or carrying unit. AVOID
sharp metal fins on front and rear coils.
■ Make sure air conditioner does not fall during
installation.
Required Tools and Equipment
• Tight-fitting gloves
• Standard screwdriver
• Phillips screwdriver
• Pliers
• Sharp knife
• Carpenters’level
• ®/e" open-end wrench or adjustable wrench
• 1
^"
hex socket and ratchet
• Tape measure
• Electric drill
• Va" drill bit
Installation Kit Parts
Window installation kit contains the following parts. Be
sure all parts are included before starting installation. If
parts are missing, contact Sears.
NOTE: Parts are listed in the order used and are
Item#
Description
Quantity
A
Window sill gasket (W x 14“)
40“
B
1 adjusting foot
1
C
Support bracket
1
D
V
b
“ hex-head screw
3
E
Sash bracket
1
F
®/
b
" Phillips screw
3
G
Window seal strip (%" x ^W)
40“