Installation Instructions (cont’d)
2, The convertible element is located behind the lower access
panel of the water heater. Remove the two screws securing
the access panel, and remove pane!.
5. Remove the screws from terminal 2 of the element, and move
the looped end of the wire aside.
3. Remove die insulation bloclc to expose the opening,.
The buss bar is labeled 5500 W. Place the buss bar over termi
nals 2 and 3 with the 5500 W visible. Install the extra screw
provided into terminal 3,
4, Lower Element; Lift out the tab as shown to unciip the
terminal cover from the thermostat. The terminal cover can
now be removed from the thermostat.
The wire removed from terminal 2 has a looped end. It must
remain looped and now be placed (as shown) on top of the
buss bar, over the opening of terminal 2, and secured using
the remaining screw.
8- Tighten terminals 2 and 3 to ensure proper electrical
connection