Product data sheets – Kenmore 2220698 User Manual
Page 22
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

PRODUCT DATA SHEETS
Cyst Interior Water Filtration System Model WFI-NLCS200/NLCS200
Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.
Capacity; 200 gallons (757 liters),
Service fiow rate: 0.5 GPM (1.89 tVmin.) @ 60 psi.
Substance Reduction
U.S. EPA
Average
Maximum
Average
Minimum %
Average %
NSF Test
Aesthetic Effects
MCL
Influent
Effluent
Effluent
Reduction
Reduction
Number
Chlorine Taste/Odor
N/A
1.9 mg/L
N/A
0.06 mg/L
N/A
97%
994707
Particulate
N/A
108,667/mL*
N/A
45/mL
N/A
99.96%
994711
Contaminant
U.S. EPA
Average
Maximum
Average
Minimum %
Average %
NSF Test
Reduction
MCL
Influent
Effluent
Effluent
Reduction
Reduction
Number
Cyst
99.95%**
157,750/mL
55/mL
1.0/mL
99.9987%
99.9996%
994710
Turbidity
N/A
26 NTU
0.5 NTU
0.1 NTU
98.9%
99.5%
994710
Lead: @ pH 6.5
0.015 mg/L
0.160 mg/L***
0.011 mg/L
0.001 mg/L
93.5%
99.4%
994708
Lead: @ pH 8.5
0.015 mg/L
0.158 mg/L***
0.011 mg/L
0.001 mg/L
92.1%
99.3%
994709
It is essential that operational, maintenance, and filter
replacement requirements be carried out for this product to
perform as advertised.
Model NLCS200
Change the cartridge at least every 6-9
months. Use replacement cartridge NLCS200, part# 9002.
2001 suggested retail price of $39.95 U.S.A./$49.95 Canada.
Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected water that may contain filterable cysts.
Refer to the “Front cover” or “Assistance or Service” section
for the Manufacturer’s name, address and telephone number.
Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
City or Well
Water Pressure
30- 120 psi (207 - 827 kPa)
Water Temperature
33°-100°F(0.6°-37.8° C)
‘Test requirement is at least 100,000 particles/ml of AC Fine Test Dust. “Cyst performance is % reduction based on NSF Standard 53. ***Test
requirement is 0.15 mg/L± 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
® NSF is a registered trademark of NSF International.
22