For the plumber, Install drains, Condenser drain – Whirlpool CHCH8WS User Manual
Page 4: Install water supply, Cdndenser water inlet, Conform to all applicable codes
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
FOR THE PLUMBER
CONFORM TO ALL APPLICABLE CODES
INSTALL DRAINS
%' O.D. RUBBER TUBE
CONDENSATE DRAI
n
H«
y."
O.D. TUBE SUPPLIED
WITH WHIRLPOOL BIN
FROM ICE MAKER PUMP PAN
t
AIR VENT-
TO OPEN DRAIN
№
------
1/8” SIPHON HOLE
VFPT
BIN DRAIN
/
V
the
NOTE: The Va" dia. siphon break hole must be in
vertical leg of white vinyl tubing.
The storage bin drains by gravity and, therefore, the drain
line must maintain gradual slope to an open drain re
ceptacle. Any rise in the drain line will cause an air lock
which will prevent the water from draining from the stor
age bin. Installation of an air vent in the drain line will
eliminate the possibility of an air lock forming.
CONDENSER DRAIN
NEEDED ONLY ON WATER COOLED MODELS
CHCH
8
WE, CHCH
8
WS
1
.
V
2
" galvanized pipe or copper tubing must be used to
extend the condenser outlet to an open type dram.
2.
Adequate flow rate must be maintained through the
condenser. Runs over 40 ft. will require using larger pipe size.
*NOTE: These drains may be connected to a disposal
system if high humidity or condenser cleaning causes liquid
in the sump areas.
INSTALL WATER SUPPLY
Water treatment may be advisable because poor quality
water can cause marginal operation or malfunction and
increase
cleaning
frequency
and
maintenance
costs.
Contact
your
local
Whirlpool
Commercial
Ice
Machine
Dealer for recommendations.
WATER COOLED
/3” O.D. RUBBER TUBE
CONDENSATE DRAIN.^
WATER COOLED
MODELS
CONDENSER
OUTLET
MPT ICE MAKER
DRAIN TUBE
WATER COOLED
CONDENSER INLET
¡/3” O.D.RUBBER TUBE
CONDENSATE DRAiN^
y»-'0
D COPPER TUBE
INLET WATER LINE
ICE MAKING HEAD Cold Water Supply V
4
o.d.
soft copper tube with shut-off valve.
1
.
A shut-off valve should be provided In the wafer
supply line at a convenient location near the ice maker.
The supply line must be adequately sized to compensate
for the length of the run.
Supply runs over 10 feet should be made with %' o.d.
copper tubing. Runs of 10 feet or less may be made with
I
4
" o.d. copper tubing.
NOTE: Always flush out water lines before connecting
to prevent foreign matter from entering the float valve.
2.
Connect supply line to V
a
" o.d. copper water line at
center rear of ice making head.
3.
Water is controlled in pump reservoir by float valve.
Make sure float valve opens and closes.
4. Water pressure must be 20 to 100 psi. If the pressure
exceeds 100 psi, a regulator will have to be installed. The
unit will operate in pressures below 20 psi; however, it
may produce cloudy ice
CDNDENSER WATER INLET
NEEDED ONLY ON WATER COOLED MODELS
CHCH
8
WE, CHCH
8
WS
1. Use a 3/8" I.P.S. independent cold water supply to the
water cooled condenser inlet for proper condenser operation.
Runs over 40 ft. will require using larger pipe size.