RECEPTACLE WIRING

RECEPTACLE WIRING should be at least as

large as size shown on electrical Chart B. Use

copper wire only. It is the personal responsibility
and obligation of the customer to provide
proper and adequate receptacle wiring installed

by a qualified electrician. OBSERVE NATIONAL
ELECTRICAL

CODE

AND

ALL

LOCAL

GOVERNING CODES AND ORDINANCES.

RECOMMENDED GROUNDING METHOD

For your personal safety, this appliance must be

grounded. This appliance is equipped with a
power supply cord having a 3-prong grounding
plug. To minimize possible shock hazard, the
cord must be plugged into a mating 3-prong
grounding type wall receptacle, grounded in
accordance with the National Electrical Code
and local codes and ordinances. If a mating wall
receptacle is not available, it is the personal
responsibility and obligation of the customer to
have a properly grounded 3-prong wall receptacle

installed by a qualified electrician.

ELECTRICAL

REQUIREMENTS

For 230 volt and 230/208 volt models with

serial plate amperes up through 16.0

Refer to Chart C for specific wiring and receptacle
information to be used.

OBSERVE

ALL

LOCAL

GOVERNING

CODES

AND ORDINANCES

Do not, under any circumstances, remove the

power supply cord ground prong.

ELECTRICAL GROUND IS REQUIRED

ON THIS APPLIANCE.

A three-wire, single-phase 60 hertz AC only
electrical supply is required.

A separate electrical supply is required on a
separately fused circuit. Do not fuse ground-
neutral.

See Chart C for receptacle voltage requirements,
proper fuse size, wire and wiring connections
which must conform with rating of the appliance.

Do not use an extension cord.

Chart-C

PLUG AND

RECEPTACLE

DATA

RECEPTACLE

PÍ ДТ

ДПР ^ OBOUND

FLAT BLADE риоцо

USETME-OELAY

FUSE

OR TIME

DELAY CtRCUrr

BREAKBI

RATING IN

AMPS

20

RECEPTACLE

VOLTAGE

(60 HERTZ

ACM AU

SiSTANCeS)

MODEL WITH

SERIAL PLATE

OF 230 VOLTS

(207 MIN,2S3

MAX.)

MODEL WITH

SERIAL PLATE

OF 230/208

VOLTS

(197.6 MIN

253 MAX )

SERIAL PLATE

AMPERES

up

through

16.0

MINIMUM

RECEPTACLE

WIRE SIZE

12 GAUGE

USE COPPER

WIRE ONLY

TYPE

OF BRANCH

CIRCUIT

SINGLE

OUTLET

ONLY

RECEPTACLE WIRING

RECEPTACLE WIRING should be at least as

large as size shown on electrical Chart C. Use

copper wire only. It is the personal responsibility
and obligation of the customer to provide

proper and adequate receptacle wiring installed
by a qualified electrician. OBSERVE NATIONAL

ELECTRICAL

CODE

AND

ALL

LOCAL

GOVERNING CODES AND ORDINANCES.

RECOMMENDED GROUNDING METHOD

For your personal safety, this appliance must be

grounded. This appliance is equipped with a
power supply cord having a 3-prong grounding
plug. To minimize possible shock hazard, the
cord must be plugged into a mating 3-prong
grounding type wall receptacle, grounded in
accordance with the National Electrical Code
and local codes and ordinances. If a mating wall

receptacle is not available, it is the personal
responsibility and obligation of the customer to
have a properly grounded 3-prong wall receptacle
installed by a qualified electrician.