D j electrical d ) requirements, Electrical ground this appliance, J electrical d ) requirements – Whirlpool ACE094XM0 User Manual
Page 4: Chart-b
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Figure 1
3-PRONG
GROUNDING PLUG
\
GROUND
PRONG 3- PRONG
GROUNDING
TYPE WALL RECEPTACLE
POWER SUPPLY CORD
D
J ELECTRICAL
D ) REQUIREMENTS
For 230 volt and 230/208 volt models with
serial plate amperes up through 12.0
Refer to Chart B for specific wiring and recep
tacle information to be used.
ALTERNATE GROUNDING METHOD
If changing and properly grounding the wall
receptacle is impossible and where local codes
permit
(consult
your
electrical
inspector),
a
temporary adapter may be plugged into the
existing 2-prong wall receptacle to mate with the
3-prong power supply cord. See Figure 2. THIS,
HOWEVER, IS NOT RECOMMENDED.
If this is done, you must connect the grounded
eyelet on the adapter to the wall receptacle
cover plate screw and from this same screw, you
must connect a separate copper ground wire
(#14 minimum) to a grounded cold water pipe.*
See Figure 2. Do not ground to a gas supply
pipe. Do not connect to electrical supply until
appliance is permanently grounded.
Figure 2
ELECTRICALLY
GROUNDED METAL
COLD WATER PIPE
(REMOVE PAINT, etc.)
GROUND ASSEMBLY
(ATTACH TO GROUNDED
METAL COLD
WATER PIPE)
COVER PLATE
di)
SCREW
ADAPTER
GROUND PRONG
■ POWER SUPPLY CORD
WALL
RECEPTACLE
*Cold water pipe must have metal continuity to
electrical ground and not be interrupted by
plastic, rubber or other electrically insulating
connectors (including water meter or pump)
without adding a jumper wire at these con
nections.
OBSERVE
ALL
LOCAL
GOVERNING
CODES
AND ORDINANCES.
Do not, under any circumstances, remove the
power supply cord ground plug.
ELECTRICAL
GROUND
THIS APPLIANCE.
IS REQUIRED ON
A three-wire, single-phase 60 hertz AC only
electrical supply is required.
A separate electrical supply is required on a
separately fused circuit. Do not fuse ground-
neutral.
See Chart B for receptacle voltage requirements,
proper fuse size, wire and wiring connections
which must conform with rating of the appliance.
Do not use an extension cord.
Chart-B
PLUG AND
RECEPTACLE
DATA
RECEPTACLE
RECEPTACLE
VOLTAGE
(M HERTZ
AC IN ALL
INSTANCES)
MODEL WITH
SERIAL PLATE
OF 230 VOLTS
(207 MIN,253
MAX )
MODEL WITH
SERIAL PLATE
OF 230/208
VOLTS
(197.6 MIN
2S3 MAX )
SERIAL PLATE
AMPERES
up
through
12.0
USE TIME-DELAY
MINIMUM
FUSE
OR TIME
RECEPTACLE
TYPE
DELAY CIRCUIT
WIRE SIZE
OF BRANCH
BREAKER
RATING IN
SEE BELOW
CIRCUIT
AMPS
14 GAUGE
SINGLE
OUTLET
USE COPPER
ONLY
15
WIRE ONLY