13
When removing gear shell from driven gear, it is not necessary to
remove gear lock bolt.
After completing the timing of the lobes bend over lock tabs on
the four gear cap screws.
19. Install gear cover [7] using same method as was used to in-
stall drive cover. (Step 18).
20. Install mounting feet [304] and secure with cap screws and
washers [307 & 80].
21. Prior to putting blower into operation, follow Installation and
Operation instructions. Observe the oil level frequently, dur-
ing the initial hours of operation. A badly installed or dam-
aged oil seal will result in oil loss.
Figure 9.
SPECIAL TOOL DRAWINGS - MODEL 4500/4600
All dimensions shown are in inches.
MODEL 4500/4600
LIP SEAL PRESSING TOOL
MODEL 4500/4600
BEARING INSTALLATION TOOL