Missing label compensation – CON-TECH CS2000-QD User Manual
Page 13
- 11 -
Missing Label Compensation
Overview:
The CS2000 has the capability to detect a single missing label and output a stop pulse as
though the label were present. In order for Missing Label Compensation to function properly the
operator must first: a) have Pulse Output selected - see Program Mode (page 12) for more
information. b) adjust the label sensitivity - see Easy Setup (page 10) for more information. c)
have the labeling machine set to desired speed.
Enabling Missing Label Compensation:
1.
Make sure a label is under the sensing area.
2.
Depress the push-button until the green LED begins flashing at a slow rate
(5 sec.), then release. If the green LED flashes at a fast rate it indicates that the
label was not positioned correctly and you need to start over.
3.
Jog 1 label.
Missing Label Compensation is now enabled and should function correctly.
Disabling Missing Label Compensation:
1.
Depress the push-button until the green LED begins flashing (5 sec.), then release.
2.
Depress the push-button once again to disable.
*You can also disable Missing Label Compensation by selecting Level Shift Output. Refer to
Program Mode (page 12) for more information.