beautypg.com

Antari LCU-1 User Manual

Page 9

background image

determine the cause of the problem, do not simply continue pushing the

remote button, as this may damage the unit. Return the machine to your

ANTARI dealer.

Cleaning your fog machine regularly will help reduce costly parts

replacement and repair charges.

Maintenance

Do not allow the fog liquid to become contaminated. Always replace the

caps on the fog liquid container and the fog machine liquid tank

immediately after filling.

After every 40 hours of continuous operation, it is recommended to run a

cleaning solution composed of 80% distilled water/20% white vinegar

through the system to prevent the accumulation of particulate matter in

the tube. The recommended cleaning regimen is as follows:

1.

While unit is unplugged and clean out debris with vinegar and a pipe

cleaner, making sure that the tube is free of clogs.

2.

Add cleaning solution to tank. Run unit in a open area until tank is

empty.

3.

Cleaning is now complete. Refill with fog liquid.

4.

Clean with a dry cloth only.

5.

Store dry.

Read and save these instructions

9