DOKuStar Validation for Ascent Capture

Page

20

OnFieldDeactivated

These events will be fired when the field was deactivated. If the

OnFieldDeactivating

event is aborted, the

current field will remain active.

Definition:

Private Sub fld_OnFieldDeactivated(ByVal Field As Field, ByVal NextField As Field)

The parameter

Field

is the field that becomes deactivated, where

NextField

is the field that will become activated.

Note that the old field contents will not be restored when the

OnFieldDeactivating

event is aborted! The

OnFieldDeactivating

event occurs after the

OnFieldChanged

event, so the changing of the value has

already taken place and cannot be taken back (see

Event Order

below).

Subfield Events

Sub-fields (e.g. table cells) have their own activation and deactivation events:

OnSubFieldActivating

,

OnSubFieldActivated

,

OnSubFieldDeactivating

and

OnSubFieldDeactivated

.

These events get the

Field

(e.g. table), the

Subfield

(the cell), and the next (or previous respectively) sub-field as

parameters.

Definitions:

Private Sub fld_OnSubFieldActivated(ByVal Field As Field, ByVal SubField As Field, ByVal
PreviousSubField As Field)

Private Sub fld_OnSubFieldDeactivated(ByVal Field As Field, ByVal SubField As Field, ByVal
NextSubField As Field)

Here,

fld

is expected to be set to the table field.

There is no ...

Changed

event for sub-fields. This is unnecessary because every change in a sub-field will result in

an

OnFieldChanged

event for the field itself, delivering both the field and the sub-field as parameters.