Technical information for the installer, Installation in kitchen cabinet with door, Fig. 14) – CDA COOKING HOB HCG 740 User Manual
Page 17: Space for connections clearance door, 30 mm
17
TECHNICAL INFORMATION
FOR THE INSTALLER
In order to install the cooktop into the
kitchen fixture, a hole with the dimen-
sions shown in fig. 13 has to be made,
bearing in mind the following:
✓
within the unit, between the bottom
of the cooktop and the upper sur-
face of a shelf there must be a clear-
ance of at least 30 mm.
It is absolutely essential that you
place a separator between the base
of the cooktop and the built-in unit
or the oven;
✓
the cooktop must be kept no less
than 200 mm away from any side
wall (fig. 13).
✓
the hob must be installed at least 60
mm from the wall.
48
0
60
0
–2
560
200
0
–2
680
500
650 mm
450 mm
INSTALLATION IN KITCHEN
CABINET WITH DOOR
(fig. 14)
It is recommended that a 30 mm clear-
ance be left between the cooktop and
the fixture surface (fig. 14).
;;
;
;;
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
@
@
@
@
;
;
;
;
;;;;;;;
;;;;;
;;;;;
30 mm
Space for
connections
Clearance
Door
Figure 12
Figure 14
Figure 13
✓
there must be a dis-
tance of at least
650 mm between
the hob and any
wall cupboard or
extractor hood posi-
tioned immediately
above (see fig. 12).
✓
if the hob is installed over a built-in
oven, there must be a distance of at
least 30 mm between the two appli-
ances. The two appliances should be
connected to the gas supply with
independent connections.