beautypg.com

Important safety instructions, Care of the opener, Save these instructions – Chamberlain CSO 1/2HP User Manual

Page 27: Warning, Care of your opener, Maintenance schedule

background image

IMPORTANT SAFETY INSTRUCTIONS

To reduce the risk of severe injury or death to persons:

1. READ AND FOLLOW ALL INSTRUCTIONS.

2. Do not permit children either to operate or to play with the opener. Keep a remote control in a

location inaccessible to children.

3. Operate opener only when the door is in full view and free from any obstruction. Keep the door in

sight until it is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.

4. Check safety reversal system monthly. See page 26. The garage door

MUST reverse on contact

with a one-inch object (or a 2x4 board laid flat) placed on the floor. If an adjustment is made to
either the force or the limit of travel, both adjustments may be needed and the safety reversal
system must be checked.

Failure to properly adjust the opener may result in severe injury or death.

5. If possible, use the manual release only when the door is in a closed position. Caution should be

taken whenever the disconnect cord is actuated with the door open.

Weak or broken springs may

cause the door to fall rapidly, causing injury or death to persons.

6. KEEP GARAGE DOORS PROPERLY BALANCED. See page 3.

An improperly balanced door may not

reverse when required and could result in severe injury or death. Repairs to cables, spring
assemblies and other hardware must be made by a professional garage door person.

7. Disconnect the electric power from the garage door opener before making any repairs or removing

the covers.

8.

SAVE THESE INSTRUCTIONS.

WARNING

WARNING

Do not exceed 8 complete cycles of door operation per hour in commercial applications.

Care of Your Opener

Once a Month

Manually operate door. If it is unbalanced or
binding, call for professional garage door service.

Check to be sure door opens and closes fully.
Adjust limits and/or force if necessary. (See pages
24 and 25.)

Repeat the safety reverse test. Make any
necessary adjustments. (See page 26.)

Twice a Year

Check chain tension. Disconnect trolley first.
Adjust if necessary (See page 10).

Once a Year

Oil door rollers, bearings and hinges. The opener
does not require additional lubrication. Do not
grease the door tracks.

Weather conditions may cause some minor
changes in door operation requiring some re-
adjustments, particularly during the first year of
operation.

Pages 24 and 25 refer to the limit and force
adjustments. Only a screwdriver is required. Follow
the instructions carefully.

Repeat the safety reverse test (page 26) after any
adjustment of limits or force.

27

Force Controls

Adjustment Label

(Located on the back panel)

KG

KG

1

3

9

7

5

1

3

9

7

5

Limit Controls

Adjustment Label

(Located on the left side panel)

INCREASE

DOWN

TRAVEL

UP

Maintenance Schedule

Limit and Force Adjustment Controls

The remote control transmitter:

The opener must learn the code of any new remote
control. Page 29 explains how to program your
garage door opener and how to erase all codes if
required. Self service of your receiver and remote
controls is not recommended. If service is needed,
call the toll-free number listed on the back page.

The transmitter battery:

The green test light will glow and the opener will
operate when the remote control is activated, as long
as there is adequate battery power.

If the test light is

dim or off, replace the battery. Also

check the test light if transmission range decreases.

The 12V battery should produce power for at least a
year.

Dispose of your old battery properly.