COMPLETELY BEFORE SERVICING.

CONDITION

POSSIBLE CAUSE

SOLUTION

No spark at pilot when Ignitor is
operated.

1. Ignition Electrode is disconnected

from ignition wire, broken or
incorrectly positioned.

2. Ignitor wire is broken.
3. Bad Piezo Ignitor.

1. Inspect and re-connect, replace

or repair as necessary.

2. Replace wire.
3. Replace Piezo Ignitor.

The Ignitor Electrode sparks,
but Pilot does not light.

1. Gas supply is turned off or supply

line shut-off valve is closed.

2. Control Knob is not in PILOT

position.

3. Control Knob not pressed in while

in PILOT position.

4. Air present in gas lines.

5. Inlet supply pressure is not within

correct settings.

6. Other conditions that should be

identified only by a qualified gas
technician.

1. Turn on gas supply or open

supply line shut-off valve.

2. Turn Control Knob to PILOT.

3. Press Control Knob in while in

the PILOT position.

4. Continue holding in Control Knob

and repeat ignition procedure
until air is bled from the lines.

5. Call local gas supplier. Adjust

inlet supply pressure to specifica-
tion: NG; 5.5” w.c.-14.0”w.c. LP;
11.0” w.c.-14.0”w.c.

6. Call qualified gas technician.

PILOT

ON

OFF

PILOT

ADJ

LO

HI

TPTH

TH

TP

Piezo Ignitor

Regulator

Pilot / Main Control

HV104

Fig. 33 Honeywell valve assembly.