— 26 —

Notes:
*1: The factory setting of "Paper Select" will be different, depending on the model classfication.
*2: In the case of selecting the thermal roll with the SW4-4, the SW4-5 will not be available. The

SW4-5 will be set to "Black Mark" status for the Black Mark version printer.

*3: The SW4-1,4-2, 4-4, and 4-5 are available for the Black Mark version printer only.

5.3 Manual Setting of Memory Switch

Memory switches can be set manually or by a command.
For manual setting, refer to the next page.
The function of each memory switch is shown in the following table.
(The

white-on-black characters

are factory setting.)

Switch No.

Setting

0 (OFF)

1 (ON)

Memory SW1-1

Power ON Info

Valid

Not send

SW1-2

Buffer Size

4k bytes

45 bytes

SW1-3

Busy Condition

Full/Err

Full

SW1-4

Receive Error

Print "?"

No Print

SW1-5

CR mode

Ignored

LF

SW1-6

Reserved

Fixed

SW1-7

DSR Signal

Invalid

Valid

SW1-8

Init Signal

Invalid

Valid

Memory SW2-1

Reserved

Fixed

SW2-2

Auto Cutter

Invalid

Valid

SW2-3

Spool Print

Invalid

Valid

SW2-4

Full Col Print

LineFeed

WaitData

SW2-5

Resume aft PE

Next

Top

SW2-6

Reserved

Fixed

SW2-7

Reserved

Fixed

SW2-8

PNE Sensor

Valid

Invalid

Memory SW3-1

Resum Cttr Err

Valid

Invalid

SW3-2

Reserved

Fixed

SW3-3

Parallel 31 Pin

Valid

Invalid

SW3-4

Reserved

Fixed

SW3-5

Reserved

Fixed

SW3-6

Reserved

Fixed

SW3-7

CBM1000 Mode

Invalid

Valid

SW3-8

Resum Open Err

Close

Command

Memory SW4-1 *3

P. Length Set

Auto Measure

Command

SW4-2 *3

Power on TOF

Invalid

Valid

SW4-3

Feed&Cut at TOF

Invalid

Valid

SW4-4 *3

Paper Select *1

Thermal Roll

BM.P / Lbl.P

SW4-5

Position detect *2

Black Mark

Label

SW4-6

Reserved

Fixed

SW4-7

Reserved

Fixed

SW4-8

Prtial Only

Invalid

Valid

Memory SW5-1

Buzzer

Valid

Invalid

SW5-2

Line Pitch

360

406

SW5-3

USB Mode

Virtual COM

Printer Class

SW5-4

Reserved

Fixed

SW5-5

Power OFF Info

Invalid

Valid

SW5-6

Reserved

Fixed

SW5-7

Reserved

Fixed

SW5-8

Reserved

Fixed