16

SUBSTANCE REDUCTION

1

AVERAGE

MAXIMUM

AVERAGE

USEPA

INFLUENT

EFFLUENT

MINIMUM

EFFLUENT

AVERAGE

SDWA

2

CONC.

CONC.

PERCENT

CONC.

PERCENT

SUBSTANCE

MCL (mg/L)

(mg/L)

(mg/L)

REMOVAL

(mg/L)

REMOVAL

Barium

2.0

9.9

1.0

90.07%

1.0

89.8%

Cadmium

0.005

0.031

0.3

99.2%

0.3

99.0%

Chromium (Hexavalent)

0.10

0.15

0.032

86.8%

0.02

86.6%

Chromium (Trivalent)

0.10

0.14

0.02

85.8%

0.02

85.7%

Copper

1.3

3.32

0.011

99.8%

0.004

99.8%

Cysts: (Including GiardiaTT

4

/99.5% Reduction117,688#/mL

5

1#/mL

99.99%

1#/mL

99.99%

Lamblia, Cryptosporidium,
and Entamoeba Histolytica)
Fluoride

4.0

13.0

1.0

99.4%

0.58

95.5%

Lead

TT

4

/0.015

0.149

1.0

99.5%

1.0

99.3%

Radium 226/228

5

5pCi/L

6

25 pCi/L

5 pCi/L

80.0%

Selenium

0.05

0.114

6

94.9%

6.0

94.7%

TDS/Sodium Chloride

500

759

75.84

89.11%

64

91.5%

1 Actual system performance may vary depending on water pressure, water temperature and other substances which may be found in water
2 United States Environmental Protection Agency (USEPA) Safe Drinking Water Act.
3 Treatment Technique requirement in effect.
4 #/mL: Particles per Milliliter.
5 Based upon approved testing methods using Barium as a surrogate. All concentrations in pCi/L: picoCurries per Liter.
6 Nitrate units are not certified for nitrate/nitrite reduction in water supplies with a pressure less than 40 psi (280 kPa). A booster pump is strongly recommended.

TESTING CONDITIONS (Complete Systems)
Temperature:
77°F ± 2°F

pH: 7.5 ± 0.5

Pressure: 50 psi

Turbidity: < 1 NTU

This system has been tested and shown to operate at its calculated recovery rating under standard test
conditions.

DIMENSIONS
Filter Assembly

7.5” W x 3” D x 16.5” H (20 cm W x 8 cm D x 42 cm H)

Storage Tank - Standard

11” Diameter x 15” H (28 cm Diameter x 38 cm H)